Factors affecting the spread and duration of epidural anesthesia with ropivacaine

被引:52
作者
Higuchi, H [1 ]
Adachi, Y [1 ]
Kazama, T [1 ]
机构
[1] Self Def Force Hanshin Hosp, Dept Anesthesia, Kawanishi, Hyogo 6660024, Japan
关键词
D O I
10.1097/00000542-200408000-00027
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
Background: Epidural anesthesia has an unpredictable extent and duration. Differences in the surface area of the lumbosacral dura, epidural fat volume, and epidural venous plexus velocity might explain the variability in the extent and duration of epidural anesthesia with ropivacaine. Methods: Twenty-six healthy patients, aged 18-45 y, undergoing peripheral orthopedic surgery were enrolled. Dural surface area and posterior epidural fat volume were calculated from low thoracic, lumbar, and sacral axial magnetic resonance images obtained at 8-mm increments. Epidural venous plexus velocity at the L3-L4 disk level was derived from phase-contrast magnetic resonance images. The patients received 100 mg ropivacaine (1.0%) epidurally. The spread and duration of sensory anesthesia was assessed by pinprick, and that of motor block was assessed using a modified Bromage scale. Statistical correlation coefficients (p) between magnetic resonance imaging and epidural anesthesia measurements were assessed by Spearman rank correlation. Stepwise multiple linear regression models were used to select important predictors of measures of epidural anesthesia. Results: Dural surface area correlated with peak sensory block level (p = -0.73, P = 0.0003) and onset time of caudal and cephalad block (p = 0.62, P = 0.002; p = -0.63, P = 0.002). Fat volume correlated with the regression to L5-S3 (p = -0.44 to -0.54, P = 0.029 to 0.007). Epidural venous plexus velocity was significantly correlated with the regression to L3 (p = -0.42, P = 0.038) and L4 (p = -0.48, P = 0.017). Multiple regression analysis revealed that dural surface area was a significant predictive variable for the peak sensory block level (R-2 = 0.61,P < 0.0001). Conclusions: These findings indicate that dural surface area influences the spread of epidural anesthesia with ropivacaine and posterior fat volume influences the duration of epidural anesthesia in healthy patients within a narrow age range. Epidural venous plexus velocity might also influence the duration of epidural anesthesia with ropivacaine.
引用
收藏
页码:451 / 460
页数:10
相关论文
共 27 条
[1]
Prediction of propofol induction dose using multiple regression analysis [J].
Adachi, YU ;
Higuchi, H .
ANESTHESIOLOGY, 2002, 96 (02) :518-518
[2]
Epidural, cerebrospinal fluid, and plasma pharmacokinetics of epidural opioids, Part 1 - Differences among opioids [J].
Bernards, CM ;
Shen, DD ;
Sterling, ES ;
Adkins, JE ;
Risler, L ;
Phillips, B ;
Ummenhofer, W .
ANESTHESIOLOGY, 2003, 99 (02) :455-465
[3]
Cerebrospinal fluid pulsation amplitude and its quantitative relationship to cerebral blood flow pulsations: A phase-contrast MR flow imaging study [J].
Bhadelia, RA ;
Bogdan, AR ;
Kaplan, RF ;
Wolpert, SM .
NEURORADIOLOGY, 1997, 39 (04) :258-264
[4]
BROMAGE PR, 1975, BRIT J ANAESTH, V47, P199
[6]
Lumbosacral cerebrospinal fluid volume is the primary determinant of sensory block extent and duration during spinal anesthesia [J].
Carpenter, RL ;
Hogan, QH ;
Liu, SS ;
Crane, B ;
Moore, J .
ANESTHESIOLOGY, 1998, 89 (01) :24-29
[7]
Clement R, 1999, J PHARMACOL EXP THER, V289, P1015
[8]
THE EFFECT OF 0.5-PERCENT ROPIVACAINE ON EPIDURAL BLOOD-FLOW [J].
DAHL, JB ;
SIMONSEN, L ;
MOGENSEN, T ;
HENRIKSEN, JH ;
KEHLET, H .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1990, 34 (04) :308-310
[9]
Chronobiology of epidural ropivacaine - Variations in the duration of action related to the hour of administration [J].
Debon, R ;
Chassard, D ;
Duflo, F ;
Boselli, E ;
Bryssine, B ;
Allaouchiche, B .
ANESTHESIOLOGY, 2002, 96 (03) :542-545
[10]
Systemic absorption and block after epidural injection of ropivacaine in healthy volunteers [J].
Emanuelsson, BMK ;
Persson, J ;
Alm, C ;
Heller, A ;
Gustafsson, LL .
ANESTHESIOLOGY, 1997, 87 (06) :1309-1317