A hydrogel-based implantable micromachined transponder for wireless glucose measurement

被引:73
作者
Lei, Ming
Baldi, Antonio
Nuxoll, Eric
Siegel, Ronald A.
Ziaie, Babak
机构
[1] Purdue Univ, Sch Elect & Comp Engn, W Lafayette, IN 47907 USA
[2] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN USA
[3] Univ Minnesota, Dept Pharmaceut, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Dept Biomed Engn, Minneapolis, MN USA
关键词
D O I
10.1089/dia.2006.8.112
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this paper, we report on the design and characterization of a new hydrogel-based implantable wireless glucose sensor. The basic device structure is a passive [inductor/ capacitor (LC)] micromachined resonator coupled to a stimuli-sensitive hydrogel, which is confined between a stiff nanoporous membrane and a thin glass diaphragm. As glucose molecules pass through the nanoporous membrane, the hydrogel swells and deflects the flexible glass diaphragm, which is the movable plate of the variable capacitor in the totally integrated passive LC resonator. The corresponding change in resonant frequency can be remotely detected. A glucose-sensitive phenylboronic acid-based hydrogel was loaded into the microtransponder, and its sensitivity and time response were measured. Prior to hydrogel loading, the sensitivity of the pressure sensor to applied air pressure was measured to be -222 kHz/kPa over the frequency range 51 --> 42 MHz. The sensor showed a sensitivity of -34.3 kHz/MM over the glucose concentration range 0-20 mM (at pH 7.4), and a response time of 90 min. The dynamic response, although unacceptable at such values, can be easily improved by decreasing the hydrogel thickness and reducing the sensor and porous membrane thicknesses. The transponder's overall dimensions were 5 X 5 X 0.8 mm(3), small enough for subcutaneous implantation.
引用
收藏
页码:112 / 122
页数:11
相关论文
共 32 条
[1]   A wireless batch sealed absolute capacitive pressure sensor [J].
Akar, O ;
Akin, T ;
Najafi, K .
SENSORS AND ACTUATORS A-PHYSICAL, 2001, 95 (01) :29-38
[2]  
Alcantar NA, 2000, J BIOMED MATER RES, V51, P343, DOI 10.1002/1097-4636(20000905)51:3<343::AID-JBM7>3.0.CO
[3]  
2-D
[4]  
[Anonymous], 1984, GEIGY SCI TABLES
[5]   A self-resonant frequency-modulated micromachined passive pressure transensor [J].
Baldi, A ;
Choi, W ;
Ziaie, B .
IEEE SENSORS JOURNAL, 2003, 3 (06) :728-733
[6]   A hydrogel-actuated environmentally sensitive microvalve for active flow control [J].
Baldi, A ;
Gu, YD ;
Loftness, PE ;
Siegel, RA ;
Ziaie, B .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2003, 12 (05) :613-621
[7]   INTERACTION OF ARENEBORONIC ACIDS WITH MONOSACCHARIDES [J].
BARKER, SA ;
CHOPRA, AK ;
HATT, BW ;
SOMERS, PJ .
CARBOHYDRATE RESEARCH, 1973, 26 (01) :33-40
[8]  
CHAU HL, 1987, IEEE T ELECTRON DEV, V34, P850, DOI 10.1109/T-ED.1987.23006
[9]  
Crank J., 1979, MATH DIFFUSION
[10]  
GU Y, 2001, 28 INT S CONTR REL B