Resistive tapered stripline (RTS) in electroencephalogram recordings during MRI

被引:14
作者
Bonmassar, G [1 ]
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, A Martinos Ctr, Charlestown, MA 02129 USA
基金
美国国家卫生研究院;
关键词
cable; electrocardiography; electroencephalography (EEG); finite difference time domain (FDTD); magnetic resonance imaging (MRI); specific absorption rate (SAR);
D O I
10.1109/TMTT.2004.832688
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 [电气工程]; 0809 [电子科学与技术];
摘要
A purely resistive stripline lead is introduced to reduce the specific absorption rate (SAR) increase due to the presence of leads in electroencephalography (EEG) measurements during magnetic resonance imaging. Discontinuities in the resistivity profile of the stripline introduce high-frequency inductive impedance that is not present in the low-frequency band of the EEG recordings. The changes in SAR introduced by the resistive tapered stripline (RTS) are studied using the finite-difference time-domain (FDTD) algorithm on a spherical phantom that models the human head. The FDTD simulations predict a reduction of the peak SAR when using RTS versus conventional resistive carbon fibers. Furthermore, our FDTD simulations have been validated on a simple prototype that exhibits no temperature increase on a spherical phantom.
引用
收藏
页码:1992 / 1998
页数:7
相关论文
共 24 条
[1]
A novel method of measuring microelectronic interconnect transmission line parameters and discontinuity equivalent electrical parameters using multiple reflections [J].
Abernethy, CE ;
Cangellaris, AC ;
Prince, JL .
IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY PART B-ADVANCED PACKAGING, 1996, 19 (01) :32-39
[2]
Metallic electrodes and leads in simultaneous EEG-MRI: Specific absorption rate (SAR) simulation studies [J].
Angelone, LM ;
Potthast, A ;
Segonne, F ;
Iwaki, S ;
Belliveau, JW ;
Bonmassar, G .
BIOELECTROMAGNETICS, 2004, 25 (04) :285-295
[3]
TIME-DOMAIN ELECTROMAGNETIC ANALYSIS OF INTERCONNECTS IN A COMPUTER CHIP PACKAGE [J].
BECKER, WD ;
HARMS, PH ;
MITTRA, R .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1992, 40 (12) :2155-2163
[4]
Chou CK, 1996, BIOELECTROMAGNETICS, V17, P195, DOI 10.1002/(SICI)1521-186X(1996)17:3<195::AID-BEM5>3.0.CO
[5]
2-Z
[6]
Safety aspects and quality assessment in MRI and MRS: A challenge for health care systems in Europe [J].
de Certaines, JD ;
Cathelineau, G .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :632-638
[7]
Investigation of the factors responsible for burns during MRI [J].
Dempsey, MF ;
Condon, B ;
Hadley, DM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :627-631
[8]
Safety of metallic implants in magnetic resonance imaging [J].
Ho, HS .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) :472-477
[9]
Radio frequency electromagnetic field exposure in humans:: Estimation of SAR distribution in the brain, effects on sleep and heart rate [J].
Huber, R ;
Schuderer, J ;
Graf, T ;
Jütz, K ;
Borbély, AA ;
Kuster, N ;
Achermann, P .
BIOELECTROMAGNETICS, 2003, 24 (04) :262-276
[10]
Itoh T., 1998, TIME DOMAIN METHODS