Comparison of homoleptic and heteroleptic 2,2′-bipyridine and 1,10-phenanthroline ruthenium complexes as chemiluminescence and electrochemiluminescence reagents in aqueous solution

被引:31
作者
Cooke, Michaela M. [1 ]
Doeven, Egan H. [2 ]
Hogan, Conor F. [2 ]
Adcock, Jacqui L. [1 ]
McDermott, Geoffrey P.
Conlan, Xavier A. [3 ]
Barnett, Neil W.
Pfeffer, Frederick M.
Francis, Paul S. [3 ]
机构
[1] Deakin Univ, Sch Lifie & Environm Sci, Geelong, Vic 3217, Australia
[2] La Trobe Univ, Dept Chem, Bundoora, Vic 3086, Australia
[3] Deakin Univ, Inst Technol Res & Innovat, Geelong, Vic 3217, Australia
关键词
Chemiluminescence; Electrochemiluminescence; Electrogenerated chemiluminescence; Heteroleptic ruthenium complexes; MIXED-LIGAND COMPLEXES; ELECTROGENERATED CHEMILUMINESCENCE; NUCLEIC-ACIDS; OXALIC-ACID; TRIS(2,2'-BIPYRIDYL)RUTHENIUM(III); BINDING; ELECTROCHEMISTRY; PHOTOCHEMISTRY;
D O I
10.1016/j.aca.2008.12.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have conducted a comprehensive comparative study of Ru(bipy)(3)(2+), Ru(bipy)(2)(phen)(2+), Ru(bipy)(phen)(2)(2+), and Ru(phen)(3)(2+) as chemiluminescence and electrochemiluminescence (ECL) reagents, to address several previous conflicting observations and gain a greater insight into their potential for chemical analysis. Clear trends were observed in many of their spectroscopic and electrochemical properties, but the relative chemiluminescence or ECL intensity with a range of analytes/co-reactants is complicated by the contribution of numerous (sometimes opposing) factors. Significantly, the reversibility of cyclic voltammetric responses for the complexes decreased as the number of phenanthroline ligands was increased, due to the lower stability of their ruthenium(III) form in the aqueous solvent. This trend was also evident over a longer timescale when the ruthenium(III) form was spectrophotometrically monitored after chemical oxidation of the ruthenium(II) complexes. In general, the greater stability of Ru(bipy)(3)(3+) resulted in lower blank signals, although this effect was less pronounced with ECL, where the reagent is oxidised in the presence of the co-reactants. Nevertheless, this shows the need to compare signal-to-blank ratios or detection limits, rather than the more common comparisons ofoverall signal intensity for different ruthenium complexes. Furthermore, our results support previous observations that, compared to Ru(bipy)(3)(2+), Ru(phen)(3)(2+) provides greater ECL and chemiluminescence intensities with oxalate, which in some circumstances translates to superior detection limits, but they do not support the subsequent generalised notion that Ru(phen)(3)(2+) is a more sensitive reagent than Ru(bipy)(3)(2+) for all analytes. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:94 / 101
页数:8
相关论文
共 50 条
[1]   Determination of selected neurotransmitter metabolites using monolithic column chromatography coupled with chemiluminescence detection [J].
Adcock, JL ;
Barnett, NW ;
Costin, JW ;
Francis, PS ;
Lewis, SW .
TALANTA, 2005, 67 (03) :585-589
[2]  
AIZAWA M, 1993, P ELECTROCHEM SOC, V93, P662
[3]   BINDING MODES AND BASE SPECIFICITY OF TRIS(PHENANTHROLINE)RUTHENIUM(II) ENANTIOMERS WITH NUCLEIC-ACIDS - TUNING THE STEREOSELECTIVITY [J].
BARTON, JK ;
GOLDBERG, JM ;
KUMAR, CV ;
TURRO, NJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1986, 108 (08) :2081-2088
[4]   Electrochemical Investigations of the Interaction of Metal Chelates with DNA. 3. Electrogenerated Chemiluminescent Investigation of the Interaction of Tris (1,10-phenanthroline) ruthenium (II) with DNA [J].
Carter, Michael T. ;
Bard, Allen J. .
BIOCONJUGATE CHEMISTRY, 1990, 1 (04) :257-263
[5]   PHOTOCHEMISTRY OF MLCT EXCITED-STATES - EFFECT OF NONCHROMOPHORIC LIGAND VARIATIONS ON PHOTOPHYSICAL PROPERTIES IN THE SERIES CIS-RU(BPY)2L22+ [J].
CASPAR, JV ;
MEYER, TJ .
INORGANIC CHEMISTRY, 1983, 22 (17) :2444-2453
[6]   Tris(2,2′-bipyridyl)ruthenium(III)-based electrochemiluminescence detector with indium/tin oxide working electrode for capillary electrophoresis [J].
Chiang, MT ;
Whang, CW .
JOURNAL OF CHROMATOGRAPHY A, 2001, 934 (1-2) :59-66
[7]   Selective determination of amino acids using flow injection analysis coupled with chemiluminescence detection [J].
Costin, JW ;
Francis, PS ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 2003, 480 (01) :67-77
[8]  
Danielson ND, 2004, MG ELEC CH, P397
[9]  
Debad JD, 2004, MG ELEC CH, P359
[10]   Analytical applications of tris(2,2′-bipyridyl)ruthenium(III) as a chemiluminescent reagent [J].
Gerardi, RD ;
Barnett, NW ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) :1-41