Optimum sample medium for single-nucleotide polymorphism and mutation detection by capillary electrophoresis

被引:11
作者
Kozlowski, P [1 ]
Krzyzosiak, WJ [1 ]
机构
[1] Polish Acad Sci, Inst Bioorgan Chem, Canc Genet Lab, PL-61704 Poznan, Poland
关键词
capillary electrophoresis; heteroduplex analysis; single-nucleotide polymorphism; single-strand conformation polymorphism;
D O I
10.1002/elps.200305782
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillary electrophoresis (CE) is a versatile analytical platform widely used for nucleic acids analysis. Its applications in research and diagnostics include scanning and screening for mutations and polymorphisms by such reliable methods as single-strand conformation polymorphism (SSCP), heteroduplex analysis (HA), and combined SSCP/HA. This study, aimed at the further development of these methods, is focused on detailed sample-media characteristics. Factors affecting single-strand conformer stability and DNA intake efficiency were analyzed. The sample media optimal for efficient mutation or SNP detection were determined, and complex SSCP-CE patterns arising from unpurified PCR products were explained. It turns out, that the nondenaturing aqueous media assure both efficient DNA intake, and single-strand conformers stability required for the SSCP and combined SSCP/HA. The results of this study are applicable to all these areas of biomedical research, in which capillary electrophoresis is used for the characterization of nucleic acids.
引用
收藏
页码:990 / 998
页数:9
相关论文
共 78 条
[1]   Improved detection and characterization of mutations by primer addition in nonradioisotopic SSCP and direct PCR sequencing [J].
Almeida, TA ;
Cabrera, VM ;
Miranda, JG .
BIOTECHNIQUES, 1998, 24 (02) :220-221
[2]   High-throughput single strand conformation polymorphism mutation detection by automated capillary array electrophoresis: Validation of the method [J].
Andersen, PS ;
Jespersgaard, C ;
Vuust, J ;
Christiansen, M ;
Larsen, LA .
HUMAN MUTATION, 2003, 21 (02) :116-122
[3]   Prediction of DNA single-strand conformation polymorphism: analysis by capillary electrophoresis and computerized DNA modeling [J].
Atha, DH ;
Kasprzak, W ;
O'Connell, CD ;
Shapiro, BA .
NUCLEIC ACIDS RESEARCH, 2001, 29 (22) :4643-4653
[4]   Detection of p53 point mutations by single strand conformation polymorphism: Analysis by capillary electrophoresis [J].
Atha, DH ;
Wenz, HM ;
Morehead, H ;
Tian, J ;
O'Connell, CD .
ELECTROPHORESIS, 1998, 19 (02) :172-179
[5]   Single-stranded conformational polymorphism analysis using automated capillary array electrophoresis apparatuses [J].
Baba, S ;
Kukita, Y ;
Higasa, K ;
Tahira, T ;
Hayashi, K .
BIOTECHNIQUES, 2003, 34 (04) :746-750
[6]  
Barker DF, 2000, HUM MUTAT, V16, P334, DOI 10.1002/1098-1004(200010)16:4<334::AID-HUMU6>3.0.CO
[7]  
2-6
[8]   Rapid genetic screening for hemochromatosis using automated SSCP-based capillary electrophoresis (SSCP-CE) [J].
Bosserhoff, AK ;
Seegers, S ;
Hellerbrand, C ;
Schölmerich, J ;
Büttner, R .
BIOTECHNIQUES, 1999, 26 (06) :1106-+
[9]   EXCESS PCR PRIMERS MAY DRAMATICALLY AFFECT SSCP EFFICIENCY [J].
CAI, QQ ;
TOUITOU, I .
NUCLEIC ACIDS RESEARCH, 1993, 21 (16) :3909-3910
[10]   Simplex optimization of electrokinetic injection of DNA in capillary electrophoresis using dilute polymer solution [J].
Catai, JR ;
Carrilho, E .
ELECTROPHORESIS, 2003, 24 (04) :648-654