Multi-frequency time-difference complex conductivity imaging of canine and human lungs using the KHU Mark1 EIT system

被引:25
作者
Kuen, Jihyeon [1 ]
Woo, Eung Je [1 ]
Seo, Jin Keun [2 ]
机构
[1] Kyung Hee Univ, Coll Elect & Informat, Seoul, South Korea
[2] Yonsei Univ, Dept Math, Seoul 120749, South Korea
关键词
EIT; complex conductivity; time difference; multi-frequency; lung; FUNCTIONAL EIT; TOMOGRAPHY; SPECTROSCOPY; VENTILATION;
D O I
10.1088/0967-3334/30/6/S10
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We evaluated the performance of the lately developed electrical impedance tomography (EIT) system KHU Mark1 through time-difference imaging experiments of canine and human lungs. We derived a multi-frequency time-difference EIT (mftdEIT) image reconstruction algorithm based on the concept of the equivalent homogeneous complex conductivity. Imaging experiments were carried out at three different frequencies of 10, 50 and 100 kHz with three different postures of right lateral, sitting (or prone) and left lateral positions. For three normal canine subjects, we controlled the ventilation using a ventilator at three tidal volumes of 100, 150 and 200 ml. Three human subjects were asked to breath spontaneously at a normal tidal volume. Real-and imaginary-part images of the canine and human lungs were reconstructed at three frequencies and three postures. Images showed different stages of breathing cycles and we could interpret them based on the understanding of the proposed mftdEIT image reconstruction algorithm. Time series of images were further analyzed by using the functional EIT (fEIT) method. Images of human subjects showed the gravity effect on air distribution in two lungs. In the canine subjects, the morphological change seems to dominate the gravity effect. We could also observe that two different types of ventilation should have affected the results. The KHU Mark1 EIT system is expected to provide reliable mftdEIT images of the human lungs. In terms of the image reconstruction algorithm, it would be worthwhile including the effects of three-dimensional current flows inside the human thorax. We suggest clinical trials of the KHU Mark1 for pulmonary applications.
引用
收藏
页码:S149 / S164
页数:16
相关论文
共 17 条
[1]  
Cheney M, 1990, Int J Imaging Syst Technol, V2, P66, DOI 10.1002/ima.1850020203
[2]   ELECTRODE MODELS FOR ELECTRIC-CURRENT COMPUTED-TOMOGRAPHY [J].
CHENG, KS ;
ISAACSON, D ;
NEWELL, JC ;
GISSER, DG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (09) :918-924
[3]   Gravity-dependent phenomena in lung ventilation determined by functional EIT [J].
Frerichs, I ;
Hahn, G ;
Hellige, G .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 :A149-A157
[4]   Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities [J].
Frerichs, I .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (02) :R1-R21
[5]   Imaging pathologic pulmonary air and fluid accumulation by functional and absolute EIT [J].
Hahn, G. ;
Just, A. ;
Dudykevych, T. ;
Frerichs, I. ;
Hinz, J. ;
Quintel, M. ;
Hellige, G. .
PHYSIOLOGICAL MEASUREMENT, 2006, 27 (05) :S187-S198
[6]   Local mechanics of the lung tissue determined by functional EIT [J].
Hahn, G ;
Frerichs, I ;
Kleyer, M ;
Hellige, G .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 :A159-A166
[7]   CHANGES IN THE THORACIC IMPEDANCE DISTRIBUTION UNDER DIFFERENT VENTILATORY CONDITIONS [J].
HAHN, G ;
SIPINKOVA, I ;
BAISCH, F ;
HELLIGE, G .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 :A161-A173
[8]  
Holder D. S., 2004, Electrical Impedance Tomography: Methods, History and Applications (Series in Medical Physics and Biomedical Engineering)
[9]  
KIM HJ, 2009, IEEE T MED IN PRESS, V28
[10]   In vivo electrical conductivity imaging of a canine brain using a 3 T MREIT system [J].
Kim, Hyung Joong ;
Oh, Tong In ;
Kim, Young Tae ;
Lee, Byung Il ;
Woo, Eung Je ;
Seo, Jin Keun ;
Lee, Soo Yeol ;
Kwon, Ohin ;
Park, Chunjae ;
Kang, Byeong Teck ;
Park, Hee Myung .
PHYSIOLOGICAL MEASUREMENT, 2008, 29 (10) :1145-1155