Hepatic MR imaging with a dynamic contrast-enhanced isotropic volumetric interpolated breath-hold examination: Feasibility, reproducibility, and technical quality

被引:124
作者
Lee, VS
Lavelle, MT
Rofsky, NM
Laub, G
Thomasson, DM
Krinsky, GA
Weinreb, JC
机构
[1] NYU, Med Ctr, Dept Radiol, New York, NY 10016 USA
[2] Siemens Med Syst Inc, Erlangen, Germany
关键词
liver; blood supply; MR; magnetic resonance (MR); pulse sequences; technology; three-dimensional; treatment planning; vascular studies;
D O I
10.1148/radiology.215.2.r00ma16365
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the feasibility, reproducibility, and technical quality of a dynamic contrast material-enhanced isotropic three-dimensional (3D) volumetric interpolated breath-hold hepatic magnetic resonance (MR) imaging examination. MATERIALS AND METHODS: Fifty patients underwent 3D spoiled gradient-echo imaging (4.2/1.8 [repetition time msec/echo time msec]; flip angle, 12 degrees; interpolation in three directions; intermittent fat saturation; pixel size less than or equal to 2.5 mm in all dimensions) before and dynamically after administration of gadopentetate dimeglumine, with the first enhanced acquisition timed for hepatic arterial dominance by using a test bolus of contrast material. Qualitative and quantitative measures of image quality were determined. Patterns of arterial and venous anatomy were assessed. Ten patients (20%) underwent repeat imaging within 6 months, and reproducibility was evaluated. RESULTS: Hepatic contrast-to-noise ratios for nonenhanced and arterial, portal venous, and equilibrium phase studies averaged 13.0 +/- 12.6 (SD), 17.4 +/- 11.8, 30.4 +/- 16.2, and 28.6 +/- 21.1, respectively. During arterial phase, the liver enhanced a mean of 29% of the maximal enhancement as measured during portal Venous phase: Hepatic vascular anatomic variants were comparable in distribution to those cited in published articles. Repeat studies were not significantly different in image quality when compared with original studies. CONCLUSION: High-quality arterial phase 3D volumetric interpolated breath-hold images can be obtained reliably and reproducibly when timed by using a test dose of contrast material.
引用
收藏
页码:365 / 372
页数:8
相关论文
共 39 条
[11]   INTRAHEPATIC PORTAL VENOUS SYSTEM - VARIATIONS DEMONSTRATED WITH DUPLEX AND COLOR DOPPLER US [J].
FRASERHILL, MA ;
ATRI, M ;
BRET, PM ;
ALDIS, AE ;
ILLESCAS, FF ;
HERSCHORN, SD .
RADIOLOGY, 1990, 177 (02) :523-526
[12]   Timing of parenchymal enhancement on dual-phase dynamic helical CT of the liver: How long does the hepatic arterial phase predominate? [J].
Frederick, MG ;
McElaney, BL ;
Singer, A ;
Park, KS ;
Paulson, EK ;
McGee, SG ;
Nelson, RC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) :1305-1310
[13]   Optimization of contrast timing for breath-hold three-dimensional MR angiography [J].
Hany, TF ;
McKinnon, GC ;
Leung, DA ;
Pfammatter, T ;
Debatin, JF .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :551-556
[14]   Hepatic lesions: Morphologic and functional characterization with multiphase breath-hold 3D gadolinium-enhanced MR angiography - Initial results [J].
Hawighorst, H ;
Schoenberg, SO ;
Knopp, MV ;
Essig, M ;
Miltner, P ;
van Kaick, G .
RADIOLOGY, 1999, 210 (01) :89-96
[15]   DUAL-PHASE HELICAL CT OF THE LIVER - VALUE OF ARTERIAL PHASE SCANS IN THE DETECTION OF SMALL (LESS-THAN-OR-EQUAL-TO-1.5-CM) MALIGNANT HEPATIC NEOPLASMS [J].
HOLLETT, MD ;
JEFFREY, RB ;
NINOMURCIA, M ;
JORGENSEN, MJ ;
HARRIS, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (04) :879-884
[16]   SIGNAL-TO-NOISE, RESOLUTION, AND BIAS FUNCTION-ANALYSIS OF ASYMMETRIC SAMPLING WITH ZERO-PADDED MAGNITUDE FT RECONSTRUCTION [J].
HURST, GC ;
HUA, JM ;
SIMONETTI, OP ;
DUERK, JL .
MAGNETIC RESONANCE IN MEDICINE, 1992, 27 (02) :247-269
[17]   Hepatic blood supply: Comparison of optimized dual phase contrast-enhanced three-dimensional MR angiography and digital subtraction angiography [J].
Kopka, L ;
Rodenwaldt, J ;
Vosshenrich, R ;
Fischer, U ;
Renner, B ;
Lorf, T ;
Graessner, J ;
Ringe, B ;
Grabbe, E .
RADIOLOGY, 1999, 211 (01) :51-58
[18]   Angiographic selection criteria for living related liver transplant donors [J].
Kostelic, JK ;
Piper, JB ;
Leef, JA ;
Lu, CT ;
Rosenblum, JD ;
Hackworth, C ;
Kahn, J ;
Thistlethwaite, JR ;
Whitington, PF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (05) :1103-1108
[19]   The effects of apnea on timing examinations for optimization of gadolinium-enhanced MRA of the thoracic aorta and arch vessels [J].
Krinsky, GA ;
Kaminer, E ;
Lee, VS ;
Rofsky, NM ;
Weinreb, JC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (05) :677-681
[20]   SEGMENTAL ANATOMY OF THE LIVER - A SONOGRAPHIC APPROACH TO THE COUINAUD NOMENCLATURE [J].
LAFORTUNE, M ;
MADORE, F ;
PATRIQUIN, H ;
BRETON, G .
RADIOLOGY, 1991, 181 (02) :443-448