Lesion patterns in patients with cryptogenic stroke with and without right-to-left-shunt

被引:26
作者
Feurer, R. [1 ]
Sadikovic, S. [1 ]
Esposito, L. [1 ]
Schwarze, J. [2 ]
Bockelbrink, A. [3 ]
Hemmer, B. [1 ]
Sander, D. [1 ]
Poppert, H. [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Neurol, D-81675 Munich, Germany
[2] Klinikum Chemnitz, Dept Neurol, Chemnitz, Germany
[3] Charite, Dept Social Med Epidemiol & Hlth Econ, D-13353 Berlin, Germany
关键词
crytogenic stroke; diffusion weighted imaging; multiple ischaemic lesions; patent foramen ovale; PATENT FORAMEN OVALE; ATRIAL SEPTAL ANEURYSM; EVENTS;
D O I
10.1111/j.1468-1331.2009.02692.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Background and purpose: Despite numerous studies, the role of patent foramen ovale (PFO) as a risk factor for stroke due to paradoxical embolism is still controversial. On the assumption that specific lesion patterns, in particular multiple acute ischaemic lesions on diffusion-weighted magnetic resonance imaging, indicate a cardioembolic origin, we compared the MRI findings in stroke patients with right-to-left shunt (RLS) and those without. Methods: The records of 486 patients with diagnosis of cerebral ischaemia were reviewed. For detection of RLS, contrast-enhanced transcranial Doppler (c-TCD) was carried out in all patients. An MRI scan of the brain was performed in all patients. Affected vascular territories were divided into anterior cerebral artery, middle cerebral artery, vertebrobasilar artery system including posterior cerebral artery, brain stem and cerebellar stroke, and strokes occurring in more than one territory. Results: We did not find a specific difference in neuroradiological lesion patterns in patients with RLS compared with patients without RLS. In particular, 23 of 165 patients (13.9%) with RLS showed multiple ischaemic lesions on MRI in comparison with 45 of 321 patients (14.0%) without RLS (P = 0.98). These findings also applied for the subgroup of cryptogenic strokes with and without RLS. Conclusion: We found no association between an ischaemic lesion pattern that is considered as being typical for stroke due to cardiac embolism and the existence of PFO. Therefore, our findings do not provide any support for the common theory of paradoxical embolism as a major cause of stroke in PFO carriers.
引用
收藏
页码:1077 / 1082
页数:6
相关论文
共 18 条
[1]
CLASSIFICATION OF SUBTYPE OF ACUTE ISCHEMIC STROKE - DEFINITIONS FOR USE IN A MULTICENTER CLINICAL-TRIAL [J].
ADAMS, HP ;
BENDIXEN, BH ;
KAPPELLE, LJ ;
BILLER, J ;
LOVE, BB ;
GORDON, DL ;
MARSH, EE ;
KASE, CS ;
WOLF, PA ;
BABIKIAN, VL ;
LICATAGEHR, EE ;
ALLEN, N ;
BRASS, LM ;
FAYAD, PB ;
PAVALKIS, FJ ;
WEINBERGER, JM ;
TUHRIM, S ;
RUDOLPH, SH ;
HOROWITZ, DR ;
BITTON, A ;
MOHR, JP ;
SACCO, RL ;
CLAVIJO, M ;
ROSENBAUM, DM ;
SPARR, SA ;
KATZ, P ;
KLONOWSKI, E ;
CULEBRAS, A ;
CAREY, G ;
MARTIR, NI ;
FICARRA, C ;
HOGAN, EL ;
CARTER, T ;
GURECKI, P ;
MUNTZ, BK ;
RAMIREZLASSEPAS, M ;
TULLOCH, JW ;
QUINONES, MR ;
MENDEZ, M ;
ZHANG, SM ;
ALA, T ;
JOHNSTON, KC ;
ANDERSON, DC ;
TARREL, RM ;
NANCE, MA ;
BUDLIE, SR ;
DIERICH, M ;
HELGASON, CM ;
HIER, DB ;
SHAPIRO, RA .
STROKE, 1993, 24 (01) :35-41
[2]
Stroke recurrence in patients with patent foramen ovale: The Lausanne Study [J].
Bogousslavsky, J ;
Garazi, S ;
Jeanrenaud, X ;
Aebischer, N ;
VanMelle, G .
NEUROLOGY, 1996, 46 (05) :1301-1305
[3]
ATRIAL SEPTAL ANEURYSM AND PATENT FORAMEN OVALE AS RISK-FACTORS FOR CRYPTOGENIC STROKE IN PATIENTS LESS-THAN 55 YEARS OF AGE - A STUDY USING TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
CABANES, L ;
MAS, JL ;
COHEN, A ;
AMARENCO, P ;
CABANES, PA ;
OUBARY, P ;
CHEDRU, F ;
GUERIN, F ;
BOUSSER, MG ;
DERECONDO, J .
STROKE, 1993, 24 (12) :1865-1873
[4]
COHNHEIM J, 1882, THROMBOSE EMBOLIE VO
[5]
INCIDENCE AND SIZE OF PATENT FORAMEN OVALE DURING THE 1ST 10 DECADES OF LIFE - AN AUTOPSY STUDY OF 965 NORMAL HEARTS [J].
HAGEN, PT ;
SCHOLZ, DG ;
EDWARDS, WD .
MAYO CLINIC PROCEEDINGS, 1984, 59 (01) :17-20
[6]
Effect of medical treatment in stroke patients with patent foramen ovale - Patent foramen ovale in Cryptogenic Stroke Study [J].
Homma, S ;
Sacco, RL ;
Di Tullio, MR ;
Sciacca, RR ;
Mohr, JP .
CIRCULATION, 2002, 105 (22) :2625-2631
[7]
Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography [J].
Jauss, M ;
Zanette, E .
CEREBROVASCULAR DISEASES, 2000, 10 (06) :490-496
[8]
Embolic lesion pattern in stroke patients with patent Foramen ovale compared with patients lacking an embolic source [J].
Jauss, Marek ;
Wessels, Tiemo ;
Trittmacher, Susan ;
Allendoerfer, Jens ;
Kaps, Manfred .
STROKE, 2006, 37 (08) :2159-2161
[9]
PREVALENCE OF PATENT FORAMEN OVALE IN PATIENTS WITH STROKE [J].
LECHAT, P ;
MAS, JL ;
LASCAULT, G ;
LORON, P ;
THEARD, M ;
KLIMCZAC, M ;
DROBINSKI, G ;
THOMAS, D ;
GROSGOGEAT, Y .
NEW ENGLAND JOURNAL OF MEDICINE, 1988, 318 (18) :1148-1152
[10]
Recurrent cerebrovascular events associated with patent foramen ovale, atrial septal aneurysm, or both. [J].
Mas, JL ;
Arquizan, C ;
Lamy, C ;
Zuber, M ;
Cabanes, L ;
Derumeaux, G ;
Coste, J .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (24) :1740-1746