Algorithms and functionality of an intensity modulated radiotherapy optimization system

被引:208
作者
Wu, QW [1 ]
Mohan, R
机构
[1] Virginia Commonwealth Univ, Med Coll Virginia, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] McGuire VA Hosp, Richmond, VA 23298 USA
关键词
intensity modulated radiotherapy; optimization; 3D treatment planning;
D O I
10.1118/1.598932
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The main purpose of this paper is to describe formalisms, algorithms, and certain unique features of a system for optimization of intensity modulated radiotherapy (IMRT). The system is coupled to a commercial treatment planning system with an accurate dose calculation engine based on the kernel superposition algorithm. The system was designed for use for research as well as for routine clinical practice. It employs dose- and dose-volume-based objective functions. The system can optimize IMRT plans with multiple target volumes simultaneously. Each target volume may be assigned a different prescription dose with constraints on either underdosing, or overdosing, or both. For organs at risk more than one constraint may be applied. This feature allows simultaneous treatment of primary, regional disease and electively treated nodes. The system allows specification of constraints on logical combinations of anatomic structures, such as a. region of overlap between the prostate planning target volume and rectum or the volume of lung excluding the tumor. The optimization may also be performed on plans which, in addition to intensity-modulated beams, include other modalities such as non-IMRT photon and electron beams and brachytherapy sources. The various features of the system are illustrated with one phantom example and two clinical examples: a brain stereotactic radiosurgery case and a nasopharynx case. In the cylindrical phantom example, the use of the system for overlap regions is demonstrated. The brain stereotactic radiosurgery example shows the improvement of IMRT plans over the conventional arcs based plan and the three-dimensional conformal plan with multiple fixed gantry angles and demonstrates the application of our system to cases where small grid sizes are important. The nasopharynx example shows the potential of IMRT to simultaneously treat large and boost fields. It also illustrates the power of IMRT to protect normal anatomic structures for highly complex situations and the efficiency in planning and delivery achievable with IMRT. The overall IMRT planning time is typically less than 2 h on a Sun Ultrasparc workstation, most of which is spent in repeated computation of dose distributions. (C) 2000 American Association of Physicists in Medicine.
引用
收藏
页码:701 / 711
页数:11
相关论文
共 36 条
[1]   COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[2]  
[Anonymous], 1993, 50 ICRU
[3]   Physical vs biological objectives for treatment plan optimization [J].
Bortfeld, T ;
Schlegel, W ;
Dykstra, C ;
Levegrun, S ;
Preiser, K .
RADIOTHERAPY AND ONCOLOGY, 1996, 40 (02) :185-185
[4]   Optimized planning using physical objectives and constraints [J].
Bortfeld, T .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) :20-+
[5]   METHODS OF IMAGE-RECONSTRUCTION FROM PROJECTIONS APPLIED TO CONFORMATION RADIOTHERAPY [J].
BORTFELD, T ;
BURKELBACH, J ;
BOESECKE, R ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1423-1434
[6]  
BORTFELD T, 1997, 12 INT C US COMP RAD, P1
[7]   Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate [J].
Burman, C ;
Chui, CS ;
Kutcher, G ;
Leibel, S ;
Zelefsky, M ;
LoSasso, T ;
Spirou, S ;
Wu, QW ;
Yang, J ;
Stein, J ;
Mohan, R ;
Fuks, Z ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04) :863-873
[8]   PEACOCK(TM) - A SYSTEM FOR PLANNING AND ROTATIONAL DELIVERY OF INTENSITY-MODULATED FIELDS [J].
CAROL, MP .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1995, 6 (01) :56-61
[9]   Optimization of intensity modulated beams with volume constraints using two methods: Cost function minimization and projections onto convex sets [J].
Cho, PS ;
Lee, S ;
Marks, RJ ;
Oh, SH ;
Sutlief, SG ;
Phillips, MH .
MEDICAL PHYSICS, 1998, 25 (04) :435-443
[10]   Multiple local minima in radiotherapy optimization problems with dose-volume constraints [J].
Deasy, JO .
MEDICAL PHYSICS, 1997, 24 (07) :1157-1161