Enhanced Wear and Corrosion in Modular Tapers in Total Hip Replacement Is Associated With the Contact Area and Surface Topography

被引:111
作者
Panagiotidou, Anna [1 ]
Meswania, Jay
Hua, Jia
Muirhead-Allwood, Sarah
Hart, Alister
Blunn, Gordon
机构
[1] Univ Coll London, Inst Orthopaed & Musculoskeletal Sci, Stanmore HA7 4LP, Middx, England
关键词
total hip replacement; modular taper; metal on metal; corrosion; wear; ARTHROPLASTY; HEADS; RETRIEVAL;
D O I
10.1002/jor.22461
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Widespread concern exists about adverse tissue reactions after metal-on-metal (MoM) total hip replacement (THR). Concerns have also been expressed with wear and corrosion of taper junctions in THR. We report the effect of surface finish and contact area associated with a single combination of materials of modular tapers. In an in vitro test, we investigated the head/neck (CoCrMo/Ti) interface of modular THRs using commercially available heads. Wear and corrosion of taper surfaces was compared following a 10 million loading cycle. Surface parameters and profiles were measured before and after testing. Electrochemical static and dynamic corrosion tests were performed under loaded and non-loaded conditions. After the load test, the surface roughness parameters on the head taper were significantly increased where the head/neck contact area was reduced. Similarly, the surface roughness parameters on the head taper were significantly increased where rough neck tapers were used. Corrosion testing showed breaching of the passive film on the rough but not the smooth neck tapers. Thus, surface area and surface finish are important factors in wear and corrosion at modular interfaces. (c) 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31:2032-2039, 2013
引用
收藏
页码:2032 / 2039
页数:8
相关论文
共 18 条
[1]
Barrack LR, 1993, J BONE JOINT SURG BR, V75B, P688
[2]
High failure rates with a large-diameter hybrid metal-on-metal total hip replacement CLINICAL, RADIOLOGICAL AND RETRIEVAL ANALYSIS [J].
Bolland, B. J. R. F. ;
Culliford, D. J. ;
Langton, D. J. ;
Millington, J. P. S. ;
Arden, N. K. ;
Latham, J. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (05) :608-615
[3]
CHMELL MJ, 1995, CLIN ORTHOP RELAT R, P77
[4]
COLLIER JP, 1991, CLIN ORTHOP RELAT R, P305
[5]
Biomechanics of large femoral heads - What they do and don't do [J].
Crowninshield, RD ;
Maloney, WJ ;
Wentz, DH ;
Humphrey, SM ;
Blanchard, CR .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :102-107
[6]
Daxiong HE, 2002, WEAR, V249, P883
[7]
IN-VIVO CORROSION OF MODULAR HIP-PROSTHESIS COMPONENTS IN MIXED AND SIMILAR METAL COMBINATIONS - THE EFFECT OF CREVICE, STRESS, MOTION, AND ALLOY COUPLING [J].
GILBERT, JL ;
BUCKLEY, CA ;
JACOBS, JJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (12) :1533-1544
[8]
Goldberg JR, 2002, CLIN ORTHOP RELAT R, P149
[9]
Metal-on-metal bearings THE EVIDENCE SO FAR [J].
Haddad, F. S. ;
Thakrar, R. R. ;
Hart, A. J. ;
Skinner, J. A. ;
Nargol, A. V. F. ;
Nolan, J. F. ;
Gill, H. S. ;
Murray, D. W. ;
Blom, A. W. ;
Case, P. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (05) :572-579
[10]
Head-neck modularity for total hip arthroplasty - Is it necessary? [J].
Hozack, WJ ;
Mesa, JJ ;
Rothman, RF .
JOURNAL OF ARTHROPLASTY, 1996, 11 (04) :397-399