Development and validation of human airway analysis algorithm using multidetector row CT

被引:66
作者
Nakano, Y [1 ]
Whittall, KP [1 ]
Kalloger, SE [1 ]
Coxson, HO [1 ]
Flint, J [1 ]
Paré, PD [1 ]
English, JC [1 ]
机构
[1] Univ British Columbia, St Pauls Hosp, McDonald Res Labs, iCAPTURE Ctr, Vancouver, BC V6Z 1Y6, Canada
来源
MEDICAL IMAGING 2002: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES | 2002年 / 4683卷
关键词
X-ray computed tomography; multi-detector row CT (multi-slice CT); human lung; airway; morphology; quantitative imaging;
D O I
10.1117/12.463615
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
There is currently no accurate method to measure airway dimensions on multidetector row computed tomography (multi-slice CT). We developed CT image analysis software to measure airway lumenal area (Ai) and airway wall area (Aaw) and compared these with quantitative morphology of excised human lungs as the gold standard. Airways identified on the CT images (1.25 mm collimation) were matched to airways identified on the lung's cut surface and Ai and Aaw were measured using custom software. The measured morphological airway lumen ranged from 1.0 to 6.4 mm in diameter. Airway dimensions obtained from CT data correlated with morphologic measurements (r = 0.96 for Ai and r = 0.91 for Aaw). However the CT systematically underestimated Ai and overestimated Aaw; average error (100 x (CT-morphology) / morphology) was -55% for Ai and +90% for Aaw. We used the morphology data to correct the CT measurements and reduced the average error to +23% for Ai and +7% for Aaw. This algorithm can be used to assess the structure and function of human airways.
引用
收藏
页码:460 / 469
页数:10
相关论文
共 23 条
[1]   ASSESSMENT OF METHACHOLINE-INDUCED AIRWAY CONSTRICTION BY ULTRAFAST HIGH-RESOLUTION COMPUTED-TOMOGRAPHY [J].
AMIRAV, I ;
KRAMER, SS ;
GRUNSTEIN, MM ;
HOFFMAN, EA .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (05) :2239-2250
[2]  
[Anonymous], 1987, AM REV RESPIR DIS, V136, P225
[3]   Airway wall thickness in patients with near fatal asthma and control groups:: assessment with high resolution computed tomographic scanning [J].
Awadh, N ;
Müller, NL ;
Park, CS ;
Abboud, RT ;
FitzGerald, JM .
THORAX, 1998, 53 (04) :248-253
[4]   Bronchial wall thickness: Appropriate window settings for thin-section CT and radiologic-anatomic correlation [J].
Bankier, AA ;
Fleischmann, D ;
Mallek, R ;
Windisch, A ;
Winkelbauer, FW ;
Kontrus, M ;
Havelec, L ;
Herold, CJ ;
Hubsch, P .
RADIOLOGY, 1996, 199 (03) :831-836
[5]   FACTORS AFFECTING THE MEASUREMENT OF SIZE AND CT-NUMBER IN COMPUTED-TOMOGRAPHY [J].
BAXTER, BS ;
SORENSON, JA .
INVESTIGATIVE RADIOLOGY, 1981, 16 (04) :337-341
[6]  
BOULET LP, 1995, EUR RESPIR J, V8, P913
[7]   AIRWAY RESPONSIVENESS AND BRONCHIAL-WALL THICKNESS IN ASTHMA WITH OR WITHOUT FIXED AIR-FLOW OBSTRUCTION [J].
BOULET, LP ;
BELANGER, M ;
CARRIER, G .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (03) :865-871
[8]   Evaluation of airways in obstructive pulmonary disease using high-resolution computed tomography [J].
King, GG ;
Müller, NL ;
Paré, D .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) :992-1004
[9]   An analysis algorithm for measuring airway lumen and wall areas from high-resolution computed tomographic data [J].
King, GG ;
Müller, NL ;
Whittall, KP ;
Xiang, QS ;
Paré, PD .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 161 (02) :574-580
[10]   AIRWAY NARROWING IN EXCISED CANINE LUNGS MEASURED BY HIGH-RESOLUTION COMPUTED-TOMOGRAPHY [J].
MCNAMARA, AE ;
MULLER, NL ;
OKAZAWA, M ;
ARNTORP, J ;
WIGGS, BR ;
PARE, PD .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 73 (01) :307-316