Electrokinetic protein preconcentration using a simple glass/poly(dimethylsiloxane) microfluidic chip

被引:199
作者
Kim, Sun Min
Burns, Mark A.
Hasselbrink, Ernest F. [1 ]
机构
[1] Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Chem Engn, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
D O I
10.1021/ac060031y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We discovered that a protein concentration device can be constructed using a simple one-layer fabrication process. Microfluidic half-channels are molded using standard procedures in PDMS; the PDMS layer is reversibly bonded to a glass base such as a microscope slide. The microfluidic channels are chevron-shaped, in mirror image orientation, with their apexes designed to pass within similar to 20 mu m of each other, forming a thin-walled section between the channels. When an electric field is applied across this thin-walled section, negatively charged proteins are observed to concentrate on the anode side of it. About 10(3)-10(6)-fold protein concentration was achieved in 30 min. Subsequent separation of two different concentrated proteins is easily achieved by switching the direction of the electric field in the direction parallel to the thin-walled section. We hypothesize that a nanoscale channel forms between the PDMS and the glass due to the weak, reversible bonding method. This hypothesis is supported by the observation that, when the PDMS and glass are irreversibly bonded, this phenomenon is not observed until a very high E-field was applied and dielectric breakdown of the PDMS is observed. We therefore suspect that the ion exclusion-enrichment effect caused by electrical double layer overlapping induces cationic selectivity of this nanochannel. This simple on-chip protein preconcentration and separation device could be a useful component in practically any PDMS-on-glass microfluidic device used for protein assays.
引用
收藏
页码:4779 / 4785
页数:7
相关论文
共 34 条
[1]   Fabrication of topologically complex three-dimensional microfluidic systems in PDMS by rapid prototyping [J].
Anderson, JR ;
Chiu, DT ;
Jackman, RJ ;
Cherniavskaya, O ;
McDonald, JC ;
Wu, HK ;
Whitesides, SH ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3158-3164
[2]   Micellar affinity gradient focusing: A new method for electrokinetic focusing [J].
Balss, KM ;
Vreeland, WN ;
Howell, PB ;
Henry, AC ;
Ross, D .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (07) :1936-1937
[3]   Simultaneous concentration and separation of enantiomers with chiral temperature gradient focusing [J].
Balss, KM ;
Vreeland, WN ;
Phinney, KW ;
Ross, D .
ANALYTICAL CHEMISTRY, 2004, 76 (24) :7243-7249
[4]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[5]   A prototype two-dimensional capillary electrophoresis system fabricated in poly(dimethylsiloxane) [J].
Chen, XX ;
Wu, HK ;
Mao, CD ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2002, 74 (08) :1772-1778
[6]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[7]   Integrated capillary electrophoresis on flexible silicone microdevices: Analysis of DNA restriction fragments and detection of single DNA molecules on microchips [J].
Effenhauser, CS ;
Bruin, GJM ;
Paulus, A ;
Ehrat, M .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3451-3457
[8]   Molding of deep polydimethylsiloxane microstructures for microfluidics and biological applications [J].
Folch, A ;
Ayon, A ;
Hurtado, O ;
Schmidt, MA ;
Toner, M .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (01) :28-34
[9]   Preconcentration of proteins on microfluidic devices using porous silica membranes [J].
Foote, RS ;
Khandurina, J ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2005, 77 (01) :57-63
[10]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897