Procedural and late outcomes following MULTI-LINK DUET coronary stent deployment

被引:29
作者
Kereiakes, DJ
Midei, M
Hermiller, J
O'Shaughnessy, C
Schlofmitz, R
Yakubov, S
Fink, S
Hu, F
Nishimura, N
Sievers, M
Valentine, ME
Broderick, T
Lansky, A
Moses, J
机构
[1] Lindner Res Ctr, Cincinnati, OH 45219 USA
[2] St Joseph Med Ctr, Baltimore, MD USA
[3] St Vincents Hosp, Indianapolis, IN USA
[4] N Ohio Heart Ctr, Elyria, OH USA
[5] St Francis Hosp, Roslyn, NY USA
[6] Riverside Methodist Hosp, Columbus, OH 43214 USA
[7] Guidant Corp, Santa Clara, CA USA
[8] Washington Hosp Ctr, Washington, DC 20010 USA
[9] Lenox Hill Hosp, New York, NY 10021 USA
关键词
D O I
10.1016/S0002-9149(99)00581-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The MULTI-LINK DUET is the next generation MULTI-LINK stent with modified strut geometry. Safety and efficacy of the MULTI-LINK DUET were evaluated in a prospective multicenter registry and were compared with prior MULTI-LINK stent experience from the ASCENT randomized trial. A total of 270 patients received 302 MULTILINK DUET stents and were evaluated using a composite primary end point of major cardiac events (death, Q-wave and non-Q-wave myocardial infarction, and requirement for coronary revascularization) attributable to the target stenosis cumulative to 30 days following enrollment. Quantitative coronary angiography was performed at a mean follow-up of 6 +/- 2 (+/-SD) months. No difference in primary end point or in angiographic restenosis to 6 months was observed between MULTI-LINK DUET and MULTI-LINK experiences. The MULTI-LINK DUET demonstrated improved device and procedural success, less postprocedural in-stent stenosis, larger postprocedural minimal lumen diameter, and fewer postprocedural marginal dissections compared with the MULTI-LINK stent, Multivariate regression modeling identified stent length, diabetes mellitus, poststent minimal lumen diameter, lesion eccentricity, and current smoking as independent predictors of in-stent restenosis. Thus, the MULTI-LINK DUET Registry demonstrates enhanced procedural performance with clinical and angiographic outcomes similar to those previously observed for the MULTI-LINK stent in the ASCENT randomized trial. (C) 1999 by Excerpta Medico, Inc.
引用
收藏
页码:1385 / 1390
页数:6
相关论文
共 16 条
[1]  
BAIM DS, 1998, CIRCULATION S1, V96, P593
[2]   Predictors of restenosis after coronary stent implantation [J].
Bauters, C ;
Hubert, E ;
Prat, A ;
Bougrimi, K ;
Van Belle, E ;
McFadden, EP ;
Amouyel, P ;
Lablanche, JM ;
Bertrand, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (06) :1291-1298
[3]  
DEJAEGERE P, 1994, CATHETER CARDIO DIAG, V32, P147
[4]   Hoop dreams - Stents without restenosis [J].
Edelman, ER ;
Rogers, C .
CIRCULATION, 1996, 94 (06) :1199-1202
[5]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[6]   STRENGTH, ELASTICITY, AND PLASTICITY OF EXPANDABLE METAL STENTS - IN-VITRO STUDIES WITH 3 TYPES OF STRESS [J].
FLUECKIGER, F ;
STERNTHAL, H ;
KLEIN, GE ;
ASCHAUER, M ;
SZOLAR, D ;
KLEINHAPPL, G .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (05) :745-750
[7]   Comparison of aggressive versus nonaggressive balloon dilatation for stent deployment on late loss and restenosis in native coronary arteries [J].
Goldberg, SL ;
Di Mario, C ;
Hall, P ;
Colombo, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (06) :708-712
[8]   Tissue proliferation within and surrounding Palmaz-Schatz stents is dependent on the aggressiveness of stent implantation technique [J].
Hoffmann, R ;
Mintz, GS ;
Mehran, R ;
Kent, KM ;
Pichard, AD ;
Satler, LF ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (08) :1170-1174
[9]   Late quantitative angiographic results after NIR Stent use: Results from the NIRVANA randomized trial and registries [J].
Lansky, AJ ;
Popma, JJ ;
Mehran, R ;
Saucedo, JF ;
Abizaid, AS ;
O'Shaughnessy, C ;
Hermiller, JB ;
Cutlip, D ;
Kuntz, RE ;
Baim, DS ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) :80A-81A
[10]   A clinical trial comparing three antithrombotic drug regimens after coronary-artery stenting [J].
Leon, MB ;
Baim, DS ;
Popma, JJ ;
Gordon, PC ;
Cutlip, DE ;
Ho, KKL ;
Giambartolome, A ;
Diver, DJ ;
Lasorda, DM ;
Williams, DO ;
Pocock, SJ ;
Kuntz, RE .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (23) :1665-1671