Comparison of aggressive versus nonaggressive balloon dilatation for stent deployment on late loss and restenosis in native coronary arteries

被引:40
作者
Goldberg, SL
Di Mario, C
Hall, P
Colombo, A
机构
[1] Harbor UCLA Med Ctr, Div Cardiol, Torrance, CA 90509 USA
[2] Ctr Cuore Columbus, Milan, Italy
关键词
D O I
10.1016/S0002-9149(97)01017-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aggressive balloon dilatation is currently performed to assure full stent expansion and minimize the risk of stent thrombosis. it is not known if aggressive stent expansion leads to further increases in intimal proliferation and restenosis. A retrospective analysis was performed of 688 consecutive coronary narrowings in which stents were implanted. Angiographic follow-up was performed and quantitative coronary angiographic measurements were obtained using electronic calipers. Patients were divided into 2 groups, Group A (212 narrowings) had stents implanted before 1993, before the routine use of aggressive stent expansion techniques. Group B (476 narrowings) had stents implanted after 1993, when oversized balloons or high-pressure inflations were performed inside stents. Comparisons were made between angiographic changes and clinical outcomes between the 2 groups, Group B lesions had less favorable characteristics due to longer lengths of lesions. Despite this there was less angiographic and clinical restenosis in this cohort, There was no difference in late loss between the 2 groups. Thus, aggressive stent implantation techniques were not associated with increased late loss or restenosis. (C) 1998 by Excerpta Medico, Inc.
引用
收藏
页码:708 / 712
页数:5
相关论文
共 15 条
[1]   RESTENOSIS AFTER CORONARY ANGIOPLASTY - THE PARADOX OF INCREASED LUMEN DIAMETER AND RESTENOSIS [J].
BEATT, KJ ;
SERRUYS, PW ;
LUIJTEN, HE ;
RENSING, BJ ;
SURYAPRANATA, H ;
DEFEYTER, P ;
VANDENBRAND, M ;
LAARMAN, GJ ;
ROELANDT, J ;
VANES, GA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) :258-266
[2]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[3]   CORONARY MORPHOLOGICAL AND CLINICAL DETERMINANTS OF PROCEDURAL OUTCOME WITH ANGIOPLASTY FOR MULTIVESSEL CORONARY-DISEASE - IMPLICATIONS FOR PATIENT SELECTION [J].
ELLIS, SG ;
VANDORMAEL, MG ;
COWLEY, MJ ;
DISCIASCIO, G ;
DELIGONUL, U ;
TOPOL, EJ ;
BULLE, TM .
CIRCULATION, 1990, 82 (04) :1193-1202
[4]   RESTENOSIS AFTER PLACEMENT OF PALMAZ-SCHATZ STENTS IN NATIVE CORONARY-ARTERIES - INITIAL RESULTS OF A MULTICENTER EXPERIENCE [J].
ELLIS, SG ;
SAVAGE, M ;
FISCHMAN, D ;
BAIM, DS ;
LEON, M ;
GOLDBERG, S ;
HIRSHFELD, JW ;
CLEMAN, MW ;
TEIRSTEIN, PS ;
WALKER, C ;
BAILEY, S ;
BUCHBINDER, M ;
TOPOL, EJ ;
SCHATZ, RA .
CIRCULATION, 1992, 86 (06) :1836-1844
[5]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[6]   BENEFIT OF INTRACORONARY ULTRASOUND IN THE DEPLOYMENT OF PALMAZ-SCHATZ STENTS [J].
GOLDBERG, SL ;
COLOMBO, A ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
TOBIS, JM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) :996-1003
[7]   MECHANISMS OF RESTENOSIS AND REDILATION WITHIN CORONARY STENTS - QUANTITATIVE ANGIOGRAPHIC ASSESSMENT [J].
GORDON, PC ;
GIBSON, CM ;
COHEN, DJ ;
CARROZZA, JP ;
KUNTZ, RE ;
BAIM, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (05) :1166-1174
[8]   INTRAVASCULAR ULTRASOUND AFTER LOW AND HIGH INFLATION PRESSURE CORONARY-ARTERY STENT IMPLANTATION [J].
GORGE, G ;
HAUDE, M ;
VOEGELE, E ;
GERBER, T ;
RUPPRECHT, HJ ;
MEYER, J ;
ERBEL, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (03) :725-730
[9]   Intracoronary stent implantation without ultrasound guidance and with replacement of conventional anticoagulation by antiplatelet therapy - 30-day clinical outcome of the French Multicenter Registry [J].
Karrillon, GJ ;
Morice, MC ;
Benveniste, E ;
Bunouf, P ;
Aubry, P ;
Cattan, S ;
Chevalier, B ;
Commeau, P ;
Cribier, A ;
Eiferman, C ;
Grollier, G ;
Guerin, Y ;
Henry, M ;
Lefevre, T ;
Livarek, B ;
Louvard, Y ;
Marco, J ;
Makowski, S ;
Monassier, JP ;
Pernes, JM ;
Rioux, P ;
Spaulding, C ;
Zemour, G .
CIRCULATION, 1996, 94 (07) :1519-1527
[10]   THE IMPORTANCE OF ACUTE LUMINAL DIAMETER IN DETERMINING RESTENOSIS AFTER CORONARY ATHERECTOMY OR STENTING [J].
KUNTZ, RE ;
SAFIAN, RD ;
CARROZZA, JP ;
FISHMAN, RF ;
MANSOUR, M ;
BAIM, DS .
CIRCULATION, 1992, 86 (06) :1827-1835