Reduction of patient exposure in pediatric radiology

被引:15
作者
Roehrig, H
Krupinski, EA
Hulett, R
机构
[1] Department of Radiology, University of Arizona, Tucson, AZ 85724
关键词
D O I
10.1016/S1076-6332(97)80203-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The authors determined whether presently used exposure levels in pediatric imaging be reduced without loss of information or a decrease in diagnostic accuracy. Materials and Methods. Multiple (stacked) image detectors filters were used to obtain identical computed radiographic images at different exposure levels of neonates with either no active lung disease or hyaline membrane disease. Physical characteristics of the images were measured. A contrast-detail study and a receiver operating characteristic study were conducted to measure observer performance. Results. Physical measurements and results of the contrast-detail study revealed that the dose-reduction images were essentially limited by x-ray quantum noise. Results of the receiver operating characteristic study indicated that diagnostic accuracy did not decrease significantly up to about 75% exposure reduction levels, although image quality rating data decreased with each exposure reduction. Conclusion. Decreasing exposure levels to about 75% of current levels may be acceptable in some clinical situations where dose is a concern, such as in pediatric imaging.
引用
收藏
页码:547 / 557
页数:11
相关论文
共 34 条
[1]   LOW-DOSE DIGITAL UROGRAPHY IN THE PREGNANT PATIENT [J].
ALBERT, SA ;
RICHTER, JO ;
ROSENFIELD, AT .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1987, 156 (04) :926-928
[2]   RADIOGRAPHIC MOTTLE - A COMPREHENSIVE THEORY [J].
BARNES, GT .
MEDICAL PHYSICS, 1982, 9 (05) :656-667
[3]  
BARNES GT, 1993, DIGITAL IMAGING, P25
[4]  
Barnett M, 1989, Radiographics, V9, P1277
[5]   CONTRAST THRESHOLDS OF THE HUMAN EYE [J].
BLACKWELL, HR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1946, 36 (11) :624-643
[6]  
Blume H, 1992, J Digit Imaging, V5, P67
[7]   PHOSPHOR PLATE COMPUTED RADIOGRAPHY - RESPONSE TO VARIATION IN MAS AT FIXED KVP IN AN ANIMAL-MODEL - POTENTIAL ROLE IN NEONATAL IMAGING [J].
BRODERICK, NJ ;
LONG, B ;
DREESEN, RG ;
COHEN, MD ;
CORY, DA ;
KATZ, BP ;
KALASINSKI, LA .
CLINICAL RADIOLOGY, 1993, 47 (01) :39-45
[8]  
COLTMAN JW, 1948, RADIOLOGY, V5, P359
[9]  
JOHNS HE, 1974, PHYSICS RADIOLOGY
[10]   MAMMOGRAPHIC FILM-PROCESSOR TEMPERATURE, DEVELOPMENT TIME, AND CHEMISTRY - EFFECT ON DOSE, CONTRAST, AND NOISE [J].
KIMMESMITH, C ;
ROTHSCHILD, PA ;
BASSETT, LW ;
GOLD, RH ;
MOLER, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (01) :35-40