Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion

被引:245
作者
Bjornsson, C. S.
Oh, S. J.
Al-Kofahi, Y. A.
Lim, Y. J.
Smith, K. L.
Turner, J. N.
De, S.
Roysam, B.
Shain, W.
Kim, S. J.
机构
[1] Seoul Natl Univ, Nano Bioelect & Syst Res Ctr, Seoul 151742, South Korea
[2] Rensselaer Polytech Inst, Dept Elect Comp & Syst Engn, Troy, NY 12180 USA
[3] Rensselaer Polytech Inst, Dept Engn Mech, Troy, NY 12180 USA
关键词
D O I
10.1088/1741-2560/3/3/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Long-term integration of neuroprosthetic devices is challenged by reactive responses that compromise the brain-device interface. The contribution of physical insertion parameters to immediate damage is not well described. We have developed an ex vivo preparation to capture real-time images of tissue deformation during device insertion using thick tissue slices from rat brains prepared with fluorescently labeled vasculature. Qualitative and quantitative assessments of damage were made for insertions using devices with different tip shapes inserted at different speeds. Direct damage to the vasculature included severing, rupturing and dragging, and was often observed several hundred micrometers from the insertion site. Slower insertions generally resulted in more vascular damage. Cortical surface features greatly affected insertion success; insertions attempted through pial blood vessels resulted in severe tissue compression. Automated image analysis techniques were developed to quantify tissue deformation and calculate mean effective strain. Quantitative measures demonstrated that, within the range of experimental conditions studied, faster insertion of sharp devices resulted in lower mean effective strain. Variability within each insertion condition indicates that multiple biological factors may influence insertion success. Multiple biological factors may contribute to tissue distortion, thus a wide variability was observed among insertions made under the same conditions.
引用
收藏
页码:196 / 207
页数:12
相关论文
共 43 条
[11]  
Harris C., 1988, Alvey Vis. Conf., V15, P10, DOI DOI 10.5244/C.2.23
[12]   Neural prostheses for vision: Designing a functional interface with retinal neurons [J].
Hetling, JR ;
Baig-Silva, MS .
NEUROLOGICAL RESEARCH, 2004, 26 (01) :21-34
[13]   Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex [J].
Kipke, DR ;
Vetter, RJ ;
Williams, JC ;
Hetke, JF .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2003, 11 (02) :151-155
[14]   Biomechanical analysis of silicon microelectrode-induced strain in the brain [J].
Lee, Hyunjung ;
Bellamkonda, Ravi V. ;
Sun, Wei ;
Levenston, Marc E. .
JOURNAL OF NEURAL ENGINEERING, 2005, 2 (04) :81-89
[15]   COCHLEAR PROSTHETICS [J].
LOEB, GE .
ANNUAL REVIEW OF NEUROSCIENCE, 1990, 13 :357-371
[16]  
MARTIN J, 1995, IAS 4 INT C INT AUT
[17]   Motor cortical representation of speed and direction during reaching [J].
Moran, DW ;
Schwartz, AB .
JOURNAL OF NEUROPHYSIOLOGY, 1999, 82 (05) :2676-2692
[18]   FINE-STRUCTURE OF PIA MATER OF RAT [J].
MORSE, DE ;
LOW, FN .
AMERICAN JOURNAL OF ANATOMY, 1972, 133 (03) :349-+
[19]   Ceramic-based multisite electrode arrays for chronic single-neuron recording [J].
Moxon, KA ;
Leiser, SC ;
Gerhardt, GA ;
Barbee, KA ;
Chapin, JK .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (04) :647-656
[20]  
Ness R, 1997, GLIA, V19, P47, DOI 10.1002/(SICI)1098-1136(199701)19:1<47::AID-GLIA5>3.0.CO