Ion suppression effects in liquid chromatography-electrospray-ionisation transport-region collision induced dissociation mass spectrometry with different serum extraction methods for systematic toxicological analysis with mass spectra libraries

被引:219
作者
Müller, C [1 ]
Schäfer, P [1 ]
Störtzel, M [1 ]
Vogt, S [1 ]
Weinmann, W [1 ]
机构
[1] Univ Freiburg Klinikum, Inst Legal Med, D-79104 Freiburg, Germany
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 773卷 / 01期
关键词
ion suppression effects; systematic toxicological analysis; mass spectra libraries;
D O I
10.1016/S1570-0232(02)00142-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ion suppression effects during electrospray-ionsation mass spectrometry (ESI-MS) caused by different sample preparation procedures for serum were investigated. This topic is of importance for systematic toxicological analysis for which LC-ESI-MS has been developed with transport-region collision-induced dissociation (ECI-CID) and mass spectra library searching. With continuous postcolumn infusion of two test compounds-codeine and glafenine-the ion suppression effects of extracted biological matrix obtained after a standard liquid-liquid extraction, a mixed-mode solid-phase extraction (SPE) method, a protein precipitation method and a combination of precipitation with polymer-based mixed-mode SPE have been investigated. Extracted ion chromatograms of codeine ([M+H](+), m/z 300) and glafenine ([M-H](-), m/z 371) were used for monitoring ion suppression. Severe ion suppression effects for codeine and glafenine were detected in positive and in negative ionisation modes, respectively, in the LC-front peak after serum clean-up with SPE (acid/neutral fraction) and protein precipitation as well as with protein precipitation combined with SPE. Less ion suppression of codeine in positive mode was found with liquid-liquid extraction of serum samples. No ion suppression was detected with the second fraction of the mixed-mode SPE (using RP-C-8 and cation-exchange phase) in both ionisation modes. All suppression effects were caused by polar and unretained matrix components, which were present after extraction and/or protein precipitation. However, no specific ion suppression was seen after elution of the polar LC-front throughout the whole gradient. It could be demonstrated, that ion suppression is not generally present at any retention time when using reversed-phase HPLC with rather long gradient programs, but may play an important role in case of high-throughput LC-MS analysis, when the analyte is not separated from the LC-front, or in flow injection analysis without chromatographic separation. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:47 / 52
页数:6
相关论文
共 14 条
  • [1] Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.3.CO
  • [2] 2-S
  • [3] ISOLATION OF ACIDIC, NEUTRAL, AND BASIC DRUGS FROM WHOLE-BLOOD USING A SINGLE MIXED-MODE SOLID-PHASE EXTRACTION COLUMN
    CHEN, XH
    FRANKE, JP
    WIJSBEEK, J
    DEZEEUW, RA
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1992, 16 (06) : 351 - 355
  • [4] JANDA I, 2002, UNPUB J CHROMATOGR B
  • [5] Mechanistic investigation of ionization suppression in electrospray ionization
    King, R
    Bonfiglio, R
    Fernandez-Metzler, C
    Miller-Stein, C
    Olah, T
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (11) : 942 - 950
  • [6] Signal enhancement for gradient reverse-phase high-performance liquid chromatography electrospray ionization mass spectrometry analysis with trifluoroacetic and other strong acid modifiers by postcolumn addition of propionic acid and isopropanol
    Kuhlmann, FE
    Apffel, A
    Fischer, SM
    Goldberg, G
    Goodley, PC
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (12) : 1221 - 1225
  • [7] Liquid chromatography-mass spectrometry:: potential in forensic and clinical toxicology
    Marquet, P
    Lachâtre, G
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 733 (1-2): : 93 - 118
  • [8] In-source CID mass spectral libraries for the "general unknown" screening of drugs and toxicants
    Marquet, P
    Venisse, N
    Lacassie, É
    Lachâtre, G
    [J]. ANALUSIS, 2000, 28 (10) : 925 - 934A
  • [9] PFLEGER K, 2000, MASS SPECTRAL GC DAT, P5
  • [10] Application of spectral libraries for high-performance liquid chromatography-atmospheric pressure ionisation mass spectrometry to the analysis of pesticide and explosive residues in environmental samples
    Schreiber, A
    Efer, J
    Engewald, W
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) : 411 - 425