Time-lapsed investigation of three-dimensional failure and damage accumulation in trabecular bone using synchrotron light

被引:99
作者
Thurner, P. J.
Wyss, P.
Voide, R.
Stauber, M.
Stampanoni, M.
Sennhauser, U.
Mueller, R.
机构
[1] Swiss Fed Inst Technol, ETH, Inst Biomed Engn, CH-8044 Zurich, Switzerland
[2] Univ Zurich, CH-8044 Zurich, Switzerland
[3] Swiss Fed Labs Mat Testing & Res, EMPA, Elect Metrol Lab, CH-8600 Dubendorf, Switzerland
[4] Paul Scherrer Inst, SLS, CH-5232 Villigen, Switzerland
关键词
synchrotron light micro-computed tomography; bone biomechanics; image-guided failure assessment; microfracture; microdamage;
D O I
10.1016/j.bone.2006.01.147
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Synchrotron radiation micro-computed tomography (SR mu CT) is a very useful technique when it comes to three-dimensional (3D) imaging of complex internal and external geometries. Being a fully non-destructive technique, SR mu CT can be combined with other experiments in situ for functional imaging. We are especially interested in the combination of SR mu CT with mechanical testing in order to gain new insights in the failure mechanism of trabecular bone. This interest is motivated by the immense costs in health care due to patients suffering from osteoporosis, a systemic skeletal disease resulting in decreased bone stability and increased fracture risk. To better investigate the different failure mechanisms on the microlevel, we have developed a novel in situ mechanical compression device, capable of exerting both static and dynamic displacements on experimental samples. The device was calibrated for mechanical testing using solid aluminum and bovine trabecular bone samples. To study different failure mechanisms in trabecular bone, we compared a fatigued and a non-fatigued bovine bone sample with respect to failure initiation and propagation. The fatigued sample failed in a burst-like fashion in contrast to the non-fatigued sample, which exhibited a distinct localized failure band. Moreover, microscopic cracks - microcracks and microfractures - were uncovered in a 3D fashion illustrating the failure process in great detail. The majority of these cracks were connected to a bone surface. The data also showed that the classification of microcracks and -fractures from 2D section can sometimes be ambiguous, which is also true for the distinction of diffuse and distinct microdamage. Detailed investigation of the failure mechanism in these samples illustrated that trabecular bone often fails in delamination, providing a mechanism for energy dissipation while conserving trabecular bone architecture. In the future, this will allow an even better understanding of bone mechanics related to its hierarchical structural organization. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:289 / 299
页数:11
相关论文
共 53 条
[1]   Damage assessment in metallic structural materials using high resolution synchrotron X-ray tomography [J].
Babout, L ;
Ludwig, W ;
Maire, E ;
Buffière, JY .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 200 :303-307
[2]   Digital volume correlation: Three-dimensional strain mapping using X-ray tomography [J].
Bay, BK ;
Smith, TS ;
Fyhrie, DP ;
Saad, M .
EXPERIMENTAL MECHANICS, 1999, 39 (03) :217-226
[3]   Microtomography using synchrotron radiation as a user experiment at beamlines BW2 and BW5 of HASYLAB at DESY [J].
Beckmann, F .
DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 :34-41
[4]   X-ray microtomography (mu CT) using phase contrast for the investigation of organic matter [J].
Beckmann, F ;
Bonse, U ;
Busch, F ;
Gunnewig, O .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (04) :539-553
[5]   X-ray computed microtomography (mu CT) using synchrotron radiation (SR) [J].
Bonse, U ;
Busch, F .
PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 1996, 65 (1-2) :133-169
[6]   VALIDITY OF THE BULK-STAINING TECHNIQUE TO SEPARATE ARTIFACTUAL FROM INVIVO BONE MICRODAMAGE [J].
BURR, DB ;
STAFFORD, T .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (260) :305-308
[7]   A COMPARISON OF THE FATIGUE BEHAVIOR OF HUMAN TRABECULAR AND CORTICAL BONE TISSUE [J].
CHOI, K ;
GOLDSTEIN, SA .
JOURNAL OF BIOMECHANICS, 1992, 25 (12) :1371-1381
[8]   EVALUATION OF ORTHOGONAL MECHANICAL-PROPERTIES AND DENSITY OF HUMAN TRABECULAR BONE FROM THE MAJOR METAPHYSEAL REGIONS WITH MATERIALS TESTING AND COMPUTED-TOMOGRAPHY [J].
CIARELLI, MJ ;
GOLDSTEIN, SA ;
KUHN, JL ;
CODY, DD ;
BROWN, MB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (05) :674-682
[9]   Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays [J].
Cloetens, P ;
Ludwig, W ;
Baruchel, J ;
Van Dyck, D ;
Van Landuyt, J ;
Guigay, JP ;
Schlenker, M .
APPLIED PHYSICS LETTERS, 1999, 75 (19) :2912-2914
[10]  
CROWELL RR, 1993, J SPINAL DISORD, V6, P175