摘要
Background A surgical guide made by the rapid prototyping (RP) technique for cup insertion in total hip arthroplasty might be useful to avoid malalignment of the cup, which indicates postoperative complications. Methods To address this research question, we applied a RP-based guide to 24 patients with their CT images. We designed it to fit onto the acetabular edge and to insert a Kirschner wire (K-wire) which indicated a planned cup direction. We intraoperatively placed it on the acetabular edge, inserted the K-wire through the guide on the superior acetabulum and implanted the cup while observing the alignment of the K-wire. We also recorded the additional time needed to use the guide. Results The mean cup accuracy between planned and postoperative alignments was 2.8 degrees (SD = 2.1 degrees) for abduction and 3.7 degrees (SD = 2.7 degrees) for anteversion. The mean additional time was 3.5 (range 2-6) min. Conclusion We can use this guide with acceptable accuracy and without consuming an excessive amount of time. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:164 / 169
页数:6
相关论文
共 30 条
[1]
An overview of economic issues in computer-assisted total joint arthroplasty [J].
Beringer, Don C. ;
Patel, Jay J. ;
Bozic, Kevin J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) :26-30
[2]
Computer-assisted orthopedic surgery with individual templates and comparison to conventional operation method [J].
Birnbaum, K ;
Schkommodau, E ;
Decker, N ;
Prescher, A ;
Klapper, U ;
Radermacher, K .
SPINE, 2001, 26 (04) :365-369
[3]
Poor accuracy of freehand cup positioning during total hip arthroplasty [J].
Bosker, B. H. ;
Verheyen, C. C. P. M. ;
Horstmann, W. G. ;
Tulp, N. J. A. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (05) :375-379
[4]
Application of computer-generated stereolithography and interpositioning template in acetabular fractures: A report of eight cases [J].
Brown, GA ;
Milner, B ;
Firoozbakhsh, K .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (05) :347-352
[5]
Comparison of two computer-assisted surgery techniques to guide a mandibular distraction osteogenesis procedure technical note [J].
d'Hauthuille, C ;
Taha, F ;
Devauchelle, B ;
Testelin, S .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (02) :197-201
[6]
Analysis of cover of the femoral head in normal and dysplastic hips NEW CT-BASED TECHNIQUE [J].
Dandachli, W. ;
Kannan, V. ;
Richards, R. ;
Shah, Z. ;
Hall-Craggs, M. ;
Witt, J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (11) :1428-1434
[7]
Comparison of a mechanical acetabular alignment guide with computer placement of the socket [J].
DiGioia, AM ;
Jaramaz, B ;
Plakseychuk, AY ;
Moody, JE ;
Nikou, C ;
LaBarca, RS ;
Levison, TJ ;
Picard, F .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :359-364
[8]
Automatic atlas-based contour extraction of anatomical structures in medical images [J].
Färber, M ;
Ehrhardt, J ;
Handels, H .
CARS 2005: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2005, 1281 :272-277
[9]
Computer-assisted total knee arthroplasty using patient-specific templating [J].
Hafez, M. A. ;
Chelule, K. L. ;
Seedhom, B. B. ;
Sherman, K. P. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (444) :184-192
[10]
HANANOUCHI T, 2008, INT J COMPUTER AS S1, V3, pS243