The effect of pressure from the table top and patient position on pelvic organ location in patients with prostate cancer

被引:26
作者
Bentel, GC [1 ]
Munley, MT [1 ]
Marks, LB [1 ]
Anscher, MS [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2000年 / 47卷 / 01期
关键词
radiation therapy; prostate irradiation; patient positioning; organ motion;
D O I
10.1016/S0360-3016(99)00403-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the impact of pressure from the table top and patient position on the relationship of the prostate, rectum, and bladder to the bony pelvis. Methods and Materials: In 9 patients with prostate cancer (3 status postprostatectomy), computed tomography (CT) scans were obtained in four positions: supine with and without false table top under the buttocks, prone with and without false table top under the lower abdomen. In four patients, a fifth scan was obtained in the first position (supine with table top in place) to assess the impact of changes in bladder/rectal fullness over time. Urination and defecation were not permitted between scans. For each patient, the four (or five) CT scans were registered to each other. Results: The anal canal and the rectum caudal to the coccyx shifted posteriorly in 7/9 patients when the support under the buttocks was removed in the supine position, When pressure from the table top was removed in the prone position, the anterior bladder extension increased. The superior rectum was adjacent to the prostate in all scans and the prostate/superior rectum/bladder generally moved together. Rectal fullness changed with time and rectal gas position was gravity-dependent and shifted with patient position. Bladder volume increased with time. Organs had shifted and/or changed fullness between the first and fifth scan obtained in the same patient position approximately 90 min apart, mostly due to increase in bladder volume. All patients found the supine position most comfortable, Conclusions: The bladder and rectal fullness vary with time, confounding the ability to attribute changes in organ location to positional factors. Pressure from the table top affects the relative location of pelvic organs and, in part, is responsible for changes previously attributed to position/gravity, (C) 2000 Elsevier Science Inc.
引用
收藏
页码:247 / 253
页数:7
相关论文
共 12 条
[1]   Analysis of prostate and seminal vesicle motion: Implications for treatment planning [J].
Beard, CJ ;
Kijewski, P ;
Bussiere, M ;
Gelman, R ;
Gladstone, D ;
Shaffer, K ;
Plunkett, M ;
Costello, P ;
Coleman, CN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (02) :451-458
[2]   THE EFFECTIVENESS OF IMMOBILIZATION DURING PROSTATE IRRADIATION [J].
BENTEL, GC ;
MARKS, LB ;
SHEROUSE, GW ;
SPENCER, DP ;
ANSCHER, MS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :143-148
[3]   ACCURACY OF PATIENT POSITIONING IN MANTLE FIELD IRRADIATION [J].
CREUTZBERG, CL ;
VISSER, AG ;
DEPORRE, PMZR ;
MEERWALDT, JH ;
ALTHOF, VGM ;
LEVENDAG, PC .
RADIOTHERAPY AND ONCOLOGY, 1992, 23 (04) :257-264
[4]   LOCALIZATION ERRORS IN MANTLE-FIELD IRRADIATION FOR HODGKINS-DISEASE [J].
HULSHOF, M ;
VANUYTSEL, L ;
VANDENBOGAERT, W ;
VANDERSCHUEREN, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (03) :679-683
[5]   Variation in prostate position quantitation and implications for three-dimensional conformal treatment planning [J].
Melian, E ;
Mageras, GS ;
Fuks, Z ;
Leibel, SA ;
Niehaus, A ;
Lorant, H ;
Zelefsky, M ;
Baldwin, B ;
Kutcher, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (01) :73-81
[6]   Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy [J].
Roeske, JC ;
Forman, JD ;
Mesina, CF ;
He, T ;
Pelizzari, CA ;
Fontenla, E ;
Vijayakumar, S ;
Chen, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1321-1329
[7]   Combined error of patient positioning variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancer [J].
Rudat, V ;
Schraube, P ;
Oetzel, D ;
Zierhut, D ;
Flentje, M ;
Wannenmacher, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (05) :1027-1034
[8]   ADVANCED PROSTATE-CANCER - THE RESULTS OF A RANDOMIZED COMPARATIVE TRIAL OF HIGH-DOSE IRRADIATION BOOSTING WITH CONFORMAL PROTONS COMPARED WITH CONVENTIONAL-DOSE IRRADIATION USING PHOTONS ALONE [J].
SHIPLEY, WU ;
VERHEY, LJ ;
MUNZENRIDER, JE ;
SUIT, HD ;
URIE, MM ;
MCMANUS, PL ;
YOUNG, RH ;
SHIPLEY, JW ;
ZIETMAN, AL ;
BIGGS, PJ ;
HENEY, NM ;
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (01) :3-12
[9]  
STROOM J, 1998, RADIOTHER ONCOL S1, V48, P109
[10]   TREATMENT PLANNING ISSUES RELATED TO PROSTATE MOVEMENT IN RESPONSE TO DIFFERENTIAL FILLING OF THE RECTUM AND BLADDER [J].
TENHAKEN, RK ;
FORMAN, JD ;
HEIMBURGER, DK ;
GERHARDSSON, A ;
MCSHAN, DL ;
PEREZTAMAYO, C ;
SCHOEPPEL, SL ;
LICHTER, AS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (06) :1317-1324