validated method for the determination of the ethanol consumption markers ethyl glucuronide, ethyl phosphate, and ethyl sulfate in human urine by reversed-phase/weak anion exchange liquid chromatography-tandem mass spectrometry

被引:85
作者
Bicker, Wolfgang
Laemmerhofer, Michael
Keller, Thomas
Schuhmacher, Rainer
Krska, Rudolf
Lindner, Wolfgang
机构
[1] Univ Vienna, Dept Analyt & Food Chem, Christian Doppler Lab Mol Recognit Mat, A-1090 Vienna, Austria
[2] Salzburg Univ, Dept Forens Med & Forens Neuropsychiat, IFFB, A-5020 Salzburg, Austria
[3] Univ Nat Resources & Appl Life Sci, Dept IFA Tulln, Christian Doppler Lab Mycotoxin Res, A-3430 Tulln, Austria
关键词
D O I
10.1021/ac060680+
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of the ethanol consumption markers ethyl glucuronide (EtG), ethyl phosphate (EtP), and ethyl sulfate (EtS) in human urine was developed. A reversed-phase/ weak anion exchange type stationary phase demonstrated particular suitability for the analysis of these highly polar acids. Sample preparation was minimized to centrifugation and dilution of urine prior to injection. The method was validated in the range of 5-750 mu g.L-1 with 1:20 and 1:1000 diluted urine, which corresponds to actual concentration ranges of 0.1-15 and 5-750 mg,L-1 in undiluted samples. Method validation was carried out using six different lots of human urine. Over the entire calibration range intraday and interday precision (each n = 5, three concentration levels per dilution factor) adopted values between 0.6 and 4.7% and 0.8 and 12.1%, relative standard deviation, respectively. Corresponding accuracy values ranged between 94.2 and 113.5% and 86.6 and 110.9%, respectively. Matrix effects (absolute/relative) were found to be present in minor extent (similar to-30% to +15% MS/MS signal alterations) and were well corrected by the employed isotopically labeled internal standards. The validated assay was applied to urine samples of a drinking study as well as postmortem specimens. It was possible to assess the principal potential of EtP as ethanol consumption marker. Elevated concentration levels were found in real samples; however, EtP seems to be less sensitive compared to the previously known ethanol phase II conjugates EtG and EtS.
引用
收藏
页码:5884 / 5892
页数:9
相关论文
共 48 条
  • [21] Ethanol formation in unadulterated postmortem tissues
    Lewis, RJ
    Johnson, RD
    Angier, MK
    Vu, NT
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2004, 146 (01) : 17 - 24
  • [22] MARALIKOVA B, 2004, GTFCH S 2003 AUSG AS, P379
  • [23] Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS
    Matuszewski, BK
    Constanzer, ML
    Chavez-Eng, CM
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (13) : 3019 - 3030
  • [24] Standard line slopes as a measure of a relative matrix effect in quantitative HPLC-MS bioanalysis
    Matuszewski, BK
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (02): : 293 - 300
  • [25] Mei H, 2005, USING MASS SPECTROMETRY FOR DRUG METABOLISM STUDIES, P103
  • [26] Chromatographic methods for the determination of markers of chronic and acute alcohol consumption
    Musshoff, F
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 781 (1-2): : 457 - 480
  • [27] Synthesis and characterization of ethyl sulfate and D5-ethyl sulfate as reference substances for applications in clinical and forensic toxicology
    Nalesso, A
    Frison, G
    Favretto, D
    Maietti, S
    Ferrara, SD
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (23) : 3612 - 3614
  • [28] Determination of ethyl glucuronide, a minor metabolite of ethanol, in human serum by liquid chromatography electrospray ionization mass spectrometry
    Nishikawa, M
    Tsuchihashi, H
    Miki, A
    Katagi, M
    Schmitt, C
    Zimmer, H
    Keller, T
    Aderjan, R
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 726 (1-2): : 105 - 110
  • [29] Alternative high-performance liquid chromatographic peptide separation and purification concept using a new mixed-mode reversed-phase/weak anion-exchange type stationary phase
    Nogueira, R
    Lämmerhofer, M
    Lindner, W
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1089 (1-2) : 158 - 169
  • [30] Silica-based monolithic columns with mixed-mode reversed-phase/weak anion-exchange selectivity principle for high-performance liquid chromatography
    Nogueira, Raquel
    Lubda, Dieter
    Leitner, Alexander
    Bicker, Wolfgang
    Maier, Norbert M.
    Laemmerhofer, Michael
    Lindner, Wolfgang
    [J]. JOURNAL OF SEPARATION SCIENCE, 2006, 29 (07) : 966 - 978