Weaning from mechanical ventilation

被引:64
作者
Alía, I [1 ]
Esteban, A [1 ]
机构
[1] Hosp Univ Getafe, Unidad Cuidados Intens, Madrid 28905, Spain
来源
CRITICAL CARE | 2000年 / 4卷 / 02期
关键词
discontinuation; intermittent mandatory ventilation; mechanical ventilation; pressure support; respiratory rate/tidal volume ratio; spontaneous breathing trials; T-tube; weaning;
D O I
10.1186/cc660
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Practice guidelines on weaning should be based on the results of several well-designed randomized studies performed over the last decade. One of those studies demonstrated that immediate extubation after successful trials of spontaneous breathing expedites weaning and reduces the duration of mechanical ventilation as compared with a more gradual discontinuation of ventilatory support. Two other studies showed that the ability to breathe spontaneously can be adequately tested by performing a trial with either T-tube or pressure support of 7 cmH(2)O lasting either 30 or 120 min. In patients with unsuccessful weaning trials, a gradual withdrawal for mechanical ventilation can be attempted while factors responsible for the ventilatory dependence are corrected. Two randomized studies found that, in difficult-to-wean patients, synchronized intermittent mandatory Ventilation (SIMV) is the most effective method of weaning.
引用
收藏
页码:72 / 80
页数:9
相关论文
共 36 条
[1]   Increased initial flow rate reduces inspiratory work of breathing during pressure support ventilation in patients with exacerbation of chronic obstructive pulmonary disease [J].
Bonmarchand, G ;
Chevron, V ;
Chopin, C ;
Jusserand, D ;
Girault, C ;
Moritz, F ;
Leroy, J ;
Pasquis, P .
INTENSIVE CARE MEDICINE, 1996, 22 (11) :1147-1154
[2]   INSPIRATORY PRESSURE SUPPORT PREVENTS DIAPHRAGMATIC FATIGUE DURING WEANING FROM MECHANICAL VENTILATION [J].
BROCHARD, L ;
HARF, A ;
LORINO, H ;
LEMAIRE, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 139 (02) :513-521
[3]   COMPARISON OF 3 METHODS OF GRADUAL WITHDRAWAL FROM VENTILATORY SUPPORT DURING WEANING FROM MECHANICAL VENTILATION [J].
BROCHARD, L ;
RAUSS, A ;
BENITO, S ;
CONTI, G ;
MANCEBO, J ;
REKIK, N ;
GASPARETTO, A ;
LEMAIRE, F .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (04) :896-903
[4]   The unassisted respiratory rate tidal volume ratio accurately predicts weaning outcome [J].
Chatila, W ;
Jacob, B ;
Guaglionone, D ;
Manthous, CA .
AMERICAN JOURNAL OF MEDICINE, 1996, 101 (01) :61-67
[5]   CLINICAL MANIFESTATIONS OF INSPIRATORY MUSCLE FATIGUE [J].
COHEN, CA ;
ZAGELBAUM, G ;
GROSS, D ;
ROUSSOS, C ;
MACKLEM, PT .
AMERICAN JOURNAL OF MEDICINE, 1982, 73 (03) :308-316
[6]  
COOK DJ, 1992, CHEST, V102, pS305
[7]   Effect on the duration of mechanical ventilation of identifying patients capable of breathing spontaneously [J].
Ely, EW ;
Baker, AM ;
Dunagan, DP ;
Burke, HL ;
Smith, AC ;
Kelly, PT ;
Johnson, MM ;
Browder, RW ;
Bowton, DL ;
Haponik, EF .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (25) :1864-1869
[8]   Effect of spontaneous breathing trial duration on outcome of attempts to discontinue mechanical ventilation [J].
Esteban, A ;
Alía, I ;
Tobin, MJ ;
Gil, A ;
Gordo, F ;
Vallverdú, I ;
Blanch, L ;
Bonet, A ;
Vázquez, A ;
de Pablo, R ;
Torres, A ;
de la Cal, MA ;
Macías, S .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (02) :512-518
[9]   A COMPARISON OF 4 METHODS OF WEANING PATIENTS FROM MECHANICAL VENTILATION [J].
ESTEBAN, A ;
FRUTOS, F ;
TOBIN, MJ ;
ALIA, I ;
SOLSONA, JF ;
VALVERDU, I ;
FERNANDEZ, R ;
DELACAL, MA ;
BENITO, S ;
TOMAS, R ;
CARRIEDO, D ;
MACIAS, S ;
BLANCO, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (06) :345-350
[10]   Extubation outcome after spontaneous breathing trials with T-tube or pressure support ventilation [J].
Esteban, A ;
Alia, I ;
Gordo, F ;
Fernandez, R ;
Solsona, JF ;
Vallverdu, I ;
Macias, S ;
Allegue, M ;
Blanco, J ;
Carriedo, D ;
Leon, M ;
delaCal, MA ;
Taboada, F ;
deVelasco, JG ;
Palazon, E ;
Carrizosa, F ;
Tomas, R ;
Suarez, J ;
Goldwasser, RS .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 156 (02) :459-465