Weaning from mechanical ventilation

被引:64
作者
Alía, I [1 ]
Esteban, A [1 ]
机构
[1] Hosp Univ Getafe, Unidad Cuidados Intens, Madrid 28905, Spain
来源
CRITICAL CARE | 2000年 / 4卷 / 02期
关键词
discontinuation; intermittent mandatory ventilation; mechanical ventilation; pressure support; respiratory rate/tidal volume ratio; spontaneous breathing trials; T-tube; weaning;
D O I
10.1186/cc660
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Practice guidelines on weaning should be based on the results of several well-designed randomized studies performed over the last decade. One of those studies demonstrated that immediate extubation after successful trials of spontaneous breathing expedites weaning and reduces the duration of mechanical ventilation as compared with a more gradual discontinuation of ventilatory support. Two other studies showed that the ability to breathe spontaneously can be adequately tested by performing a trial with either T-tube or pressure support of 7 cmH(2)O lasting either 30 or 120 min. In patients with unsuccessful weaning trials, a gradual withdrawal for mechanical ventilation can be attempted while factors responsible for the ventilatory dependence are corrected. Two randomized studies found that, in difficult-to-wean patients, synchronized intermittent mandatory Ventilation (SIMV) is the most effective method of weaning.
引用
收藏
页码:72 / 80
页数:9
相关论文
共 36 条
[31]  
SASSOON CSH, 1994, CRIT CARE MED, V22, P1933
[32]   MECHANICAL VENTILATION [J].
SLUTSKY, AS .
CHEST, 1993, 104 (06) :1833-1859
[33]   EFFECT OF LOW-LEVEL PEEP ON INSPIRATORY WORK OF BREATHING IN INTUBATED PATIENTS, BOTH WITH HEALTHY LUNGS AND WITH COPD [J].
SYDOW, M ;
GOLISCH, W ;
BUSCHER, H ;
ZINSERLING, J ;
CROZIER, TA ;
BURCHARDI, H .
INTENSIVE CARE MEDICINE, 1995, 21 (11) :887-895
[34]   Comparison of pressure- and flow-triggered pressure-support ventilation on weaning parameters in patients recovering from acute respiratory failure [J].
Tutuncu, AS ;
Cakar, N ;
Camci, E ;
Esen, F ;
Telci, L ;
Akpir, K .
CRITICAL CARE MEDICINE, 1997, 25 (05) :756-760
[35]   Clinical characteristics, respiratory functional parameters, and outcome of a two-hour T-piece trial in patients weaning from mechanical ventilation [J].
Vallverdú, I ;
Calaf, N ;
Subirana, M ;
Net, A ;
Benito, S ;
Mancebo, J .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (06) :1855-1862
[36]   A PROSPECTIVE-STUDY OF INDEXES PREDICTING THE OUTCOME OF TRIALS OF WEANING FROM MECHANICAL VENTILATION [J].
YANG, KL ;
TOBIN, MJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (21) :1445-1450