Three-dimensional model of lesion geometry for evaluation of MR-guided thermal ablation therapy

被引:12
作者
Lazebnik, RS
Weinberg, BD
Breen, MS
Lewin, JS
Wilson, DL
机构
[1] Case Western Reserve Univ, Cleveland, OH 44106 USA
[2] Univ Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
[3] Univ Hosp Cleveland, Dept Biomed Engn, Cleveland, OH 44106 USA
[4] Univ Hosp Cleveland, Sch Med, Cleveland, OH 44106 USA
[5] Univ Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
关键词
magnetic resonance (MR); guidance; image processing; phantoms; radiofrequency (RF) ablation;
D O I
10.1016/S1076-6332(03)80514-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. High-radiofrequency energy is used clinically to ablate pathologic tissue with interventional magnetic resonance (MR) imaging. For many tissues, resulting lesions have a characteristic appearance on contrast-enhanced T1- and T2-weighted MR images, with two boundaries enclosing an inner hypointense region and an outer hyperintense margin. Geometric modeling of three-dimensional thermal lesions in animal experiments and patient treatments would improve analyses and visualization. Materials and Methods. The authors created a model with two quadric surfaces and 12 parameters to describe both lesion surfaces. Parameters were estimated with iterative optimization to minimize the sum of the squared shortest distances from segmented points to the model surface. The authors validated the estimation process with digital lesion phantoms that simulated varying levels of segmentation error and missing surface information. They also applied their method to in vivo images of lesions in a rabbit model. Results. For simulated phantom lesions, the lesion geometry was accurate despite manual segmentation error and incomplete surface data. Even when 50% of the surface was missing, the median error was less than 0.5 mm. For all in vivo lesions, the median distance from the model surface to data was no more than 0.58 mm for both inner and outer surfaces, less than a voxel width (0.7 mm). The interquartile range was 0.89 mm or less for all data. Conclusion. The authors' model provides a good approximation of actual lesion geometry and is highly resistant to missing segmentation information. It should prove useful for three-dimensional lesion visualization, volume estimation, automated segmentation, and volume registration.
引用
收藏
页码:1128 / 1138
页数:11
相关论文
共 23 条
[1]  
Aschoff AJ, 2000, J MAGN RESON IMAGING, V12, P584, DOI 10.1002/1522-2586(200010)12:4<584::AID-JMRI10>3.0.CO
[2]  
2-W
[3]   Radio-frequency tumor ablation: Internally cooled electrode versus saline-enhanced technique in an aggressive rabbit tumor model [J].
Boehm, T ;
Malich, A ;
Goldberg, SN ;
Reichenbach, JR ;
Hilger, I ;
Hauff, P ;
Reinhardt, M ;
Fleck, M ;
Kaiser, WA .
RADIOLOGY, 2002, 222 (03) :805-813
[4]   Three dimensional correlation of MR images to muscle tissue response for interventional MRI thermal ablation [J].
Breen, MS ;
Lancaster, TL ;
Lazebnik, RS ;
Aschoff, AJ ;
Nour, SG ;
Lewin, JS ;
Wilson, DL .
MEDICAL IMAGING 2001: VISUALIZATION, DISPLAY, AND IMAGE-GUIDED PROCEDURES, 2001, 4319 :211-220
[5]   Calculated RF electric field and temperature distributions in RF thermal ablation: Comparison with gel experiments and liver imaging [J].
Cheng, YCN ;
Brown, RW ;
Chung, YC ;
Duerk, JL ;
Fujita, H ;
Lewin, JS ;
Schuele, DE ;
Shvartsman, S .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :70-76
[6]   Generation and observation of radio frequency thermal lesion ablation for interventional magnetic resonance imaging [J].
Chung, YC ;
Duerk, JL ;
Lewin, JS .
INVESTIGATIVE RADIOLOGY, 1997, 32 (08) :466-474
[7]   Percutaneous radiofrequency tissue ablation: Optimization of pulsed radiofrequency technique to increase coagulation necrosis [J].
Goldberg, SN ;
Stein, MC ;
Gazelle, GS ;
Sheiman, RG ;
Kruskal, JB ;
Clouse, ME .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (07) :907-916
[8]  
GOLDBERG SN, 1995, ACAD RADIOL, V2, P670
[9]  
GOLDBERG SN, 1995, ACAD RADIOL, V2, P399
[10]   Monitoring of radio frequency tissue ablation in an interventional magnetic resonance environment - Preliminary ex vivo and in vivo results [J].
Goldberg, SN ;
Gazelle, GS ;
Debatin, JF .