Monitoring of radio frequency tissue ablation in an interventional magnetic resonance environment - Preliminary ex vivo and in vivo results

被引:54
作者
Goldberg, SN
Gazelle, GS
Debatin, JF
机构
[1] UNIV ZURICH HOSP, MR CTR, INST DIAGNOST RADIOL, DEPT MED RADIOL, CH-8091 ZURICH, SWITZERLAND
[2] HARVARD UNIV, MASSACHUSETTS GEN HOSP, SCH MED, DEPT RADIOL, BOSTON, MA USA
关键词
radio frequency ablation; magnetic resonance; guidance; temperature monitoring; interventional procedures; technology;
D O I
10.1097/00004424-199711000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors evaluate the feasibility of monitoring radio frequency (RF) ablation in an interventional, open-configuration, 0.5-tesla magnetic resonance (MR) environment. METHODS. Ex vivo and in vivo RF coagulation necrosis were induced in porcine paraspinal muscle tissue using a 300 kHz monopolar RF generator applying 5 to 20 W over 3 to 9 minutes. Images were acquired simultaneous to RF application, after RF application, and in an intermittent mode (60 seconds of RF followed by 15 seconds of MR imaging). Temperature changes were monitored based on amplitude (ex vivo) and phase alterations (in vivo) of a T1-weighted graded refocused echo (GRE) sequence enabling an update every 2.5 seconds. A standardized color-coded subtraction technique enhanced signal changes. Additionally, T2- and T1-weighted spin echo (SE) images were acquired with and without intravenous contrast. Macroscopic coagulation size was compared with lesion size seen on MR images. RESULTS. Although lesion diameters were related directly to applied RF power, the application mode-had no significant impact on coagulation size (P > 0.05). As could be expected, MR imaging during RF ablation resulted in major image distortion. Radio frequency effects were seen on images acquired in the continuous and intermittent modes. Coagulation size seen on GRE images correlated well with macroscopy both ex vivo (r = 0.89) and in vivo (r = 0.92). Poorer correlation was found with postinterventional SE sequences (r = 0.78-0.84). CONCLUSIONS. Magnetic resonance monitoring of RF effects is feasible both ex vivo as well as in vivo using temperature-sensitive sequences in an open-configuration MR environment.
引用
收藏
页码:671 / 678
页数:8
相关论文
共 26 条
[1]  
ANZAI Y, 1995, AM J NEURORADIOL, V16, P39
[2]   HEPATOCELLULAR-CARCINOMA - CT AND MR FEATURES AFTER TRANSCATHETER ARTERIAL EMBOLIZATION AND PERCUTANEOUS ETHANOL INJECTION [J].
BARTOLOZZI, C ;
LENCIONI, R ;
CARAMELLA, D ;
FALASCHI, F ;
CIONI, R ;
DICOSCIO, G .
RADIOLOGY, 1994, 191 (01) :123-128
[3]  
BOTNAR R, 1997, M INT SOC MAGN RES M
[4]  
BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
[5]   Optimization of spoiled gradient-echo phase imaging for in vivo localization of a focused ultrasound beam [J].
Chung, AH ;
Hynynen, K ;
Colucci, V ;
Oshio, K ;
Cline, HE ;
Jolesz, FA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (05) :745-752
[6]  
CHUNG YC, 1996, 1996 M INT SOC MAGN
[7]   NONINVASIVE TEMPERATURE IMAGING USING DIFFUSION MRI [J].
DELANNOY, J ;
CHEN, CN ;
TURNER, R ;
LEVIN, RL ;
LEBIHAN, D .
MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) :333-339
[8]  
DEPOORTER J, 1995, MAGNET RESON MED, V33, P74, DOI 10.1002/mrm.1910330111
[9]  
GOLDBERG SN, 1995, ACAD RADIOL, V2, P670
[10]   Radiofrequency tissue ablation: Importance of local temperature along the electrode tip exposure in determining lesion shape and size [J].
Goldberg, SN ;
Gazelle, GS ;
Halpern, EF ;
Rittman, WJ ;
Mueller, PR ;
Rosenthal, DI .
ACADEMIC RADIOLOGY, 1996, 3 (03) :212-218