Voltammetric measurement of arsenic in natural waters

被引:97
作者
Feeney, R [1 ]
Kounaves, SP [1 ]
机构
[1] Tufts Univ, Dept Chem, Medford, MA 02155 USA
基金
美国国家科学基金会;
关键词
arsenic; stripping analysis; voltammetry; microfabricted arrays; on-site measurements;
D O I
10.1016/S0039-9140(02)00253-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There are several U.S. EPA approved methodologies for the determination of arsenic in ground water. Such technologies are lab-based, time intensive and can lead to a large capital cost for multi-sample analysis. In light of the number of sites found to contain arsenic at levels higher than the maximum contaminant level (MCL), on-site screening and monitoring systems are an attractive alternative. This review article summarizes several examples in the recent literature to illustrate the breadth of work in voltammetric analysis of arsenic in environmental samples. Also, included are recent voltammetric results, obtained with a microfabricated gold array and a field portable potentiostat, at an arsenic contaminated site in southern New Jersey. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:23 / 31
页数:9
相关论文
共 36 条
[1]  
Adeloju SB, 1997, ANAL LETT, V30, P147, DOI 10.1080/00032719708002297
[2]   Mercury-plated iridium-based microelectrode arrays for trace metals detection by voltammetry: Optimum conditions and reliability [J].
Belmont, C ;
Tercier, ML ;
Buffle, J ;
Fiaccabrino, GC ;
KoudelkaHep, M .
ANALYTICA CHIMICA ACTA, 1996, 329 (03) :203-214
[3]   TRACE DETERMINATION OF AS(III) AND AS(V) IN NATURAL-WATERS BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY [J].
BODEWIG, FG ;
VALENTA, P ;
NURNBERG, HW .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 311 (03) :187-191
[4]  
CHANG LW, 1996, TOXICOLOGY METALS, P48
[5]   DETERMINATION OF TOTAL ARSENIC AT NANOGRAM LEVEL BY HIGH-SPEED ANODIC-STRIPPING VOLTAMMETRY [J].
DAVIS, PH ;
DULUDE, GR ;
GRIFFIN, RM ;
MATSON, WR ;
ZINK, EW .
ANALYTICAL CHEMISTRY, 1978, 50 (01) :137-143
[6]  
Dhar RK, 1997, CURR SCI INDIA, V73, P48
[7]   Determination of total arsenic in soils by differential-pulse cathodic stripping voltammetry [J].
Eguiarte, I ;
Alonso, RM ;
Jimenez, RM .
ANALYST, 1996, 121 (12) :1835-1838
[8]  
*EIN, NAT PRIOR SIT FACT S
[9]   On-site analysis of arsenic in groundwater using a microfabricated gold ultramicroelectrode array [J].
Feeney, R ;
Kounaves, SP .
ANALYTICAL CHEMISTRY, 2000, 72 (10) :2222-2228
[10]   DETERMINATION OF ARSENIC BY ANODIC-STRIPPING VOLTAMMETRY AND DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY [J].
FORSBERG, G ;
OLAUGHLIN, JW ;
MEGARGLE, RG ;
KOIRTYOHANN, SR .
ANALYTICAL CHEMISTRY, 1975, 47 (09) :1586-1592