Application of N-PLS calibration to the simultaneous determination of Cu2+, Cd2+ and Pb2+ using peptide modified electrochemical sensors

被引:37
作者
Chow, Edith [1 ]
Ebrahimi, Diako [1 ]
Gooding, J. Justin [1 ]
Hibbert, D. Brynn [1 ]
机构
[1] Univ New S Wales, Sch Chem, Sydney, NSW 2052, Australia
关键词
D O I
10.1039/b604690h
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
The simultaneous determination of Cu2+, Cd2+ and Pb2+ is demonstrated at four modified gold electrodes using N-PLS calibration. Three of the electrodes were modified with the peptides Gly-Gly-His, gamma-Glu-Cys Gly and human angiotensin I which were covalently attached to thioctic acid self-assembled monolayers and the fourth electrode was modified with thioctic acid only. Voltammetry at the modified electrodes in the presence of the three metal ions revealed one peak due to the reduction of copper and another due to the overlapping peaks of cadmium and lead which made quantification using conventional methods difficult. N-PLS was used to calibrate and predict trace concentrations (100 nM to 10 mM) of mixtures of Cu2+, Cd2+ and Pb2+.
引用
收藏
页码:1051 / 1057
页数:7
相关论文
共 39 条
[1]
COPPER(II) COMPLEXES OF GLYCYL-L-HISTIDINE, GLYCYL-L-HISTIDYLGLYCINE, AND GLYCYLGLYCYL-L-HISTIDINE IN AQUEOUS-SOLUTION [J].
AIBA, H ;
YOKOYAMA, A ;
TANAKA, H .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1974, 47 (06) :1437-1441
[2]
Cross-reactive chemical sensor arrays [J].
Albert, KJ ;
Lewis, NS ;
Schauer, CL ;
Sotzing, GA ;
Stitzel, SE ;
Vaid, TP ;
Walt, DR .
CHEMICAL REVIEWS, 2000, 100 (07) :2595-2626
[3]
The N-way Toolbox for MATLAB [J].
Andersson, CA ;
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 52 (01) :1-4
[4]
Bacterial metal-resistance proteins and their use in biosensors for the detection of bioavailable heavy metals [J].
Bontidean, I ;
Lloyd, JR ;
Hobman, JL ;
Wilson, JR ;
Csöregi, E ;
Mattiasson, B ;
Brown, NL .
JOURNAL OF INORGANIC BIOCHEMISTRY, 2000, 79 (1-4) :225-229
[5]
Detection of heavy metal ions at femtomolar levels using protein-based biosensors [J].
Bontidean, I ;
Berggren, C ;
Johansson, G ;
Csöregi, E ;
Mattiasson, B ;
Lloyd, JA ;
Jakeman, KJ ;
Brown, NL .
ANALYTICAL CHEMISTRY, 1998, 70 (19) :4162-4169
[6]
Introduction to multivariate calibration in analytical chemistry [J].
Brereton, RG .
ANALYST, 2000, 125 (11) :2125-2154
[7]
PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[8]
Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.0.CO
[9]
2-C
[10]
Non-invasive determination of ethanol, propylene glycol and water in a multi-component pharmaceutical oral liquid by direct measurement through amber plastic bottles using Fourier transform near-infrared spectroscopy [J].
Broad, NW ;
Jee, RD ;
Moffat, AC ;
Eaves, MJ ;
Mann, WC ;
Dziki, W .
ANALYST, 2000, 125 (11) :2054-2058