Symbolic time series analysis of ultrasonic signals for fatigue damage monitoring in polycrystalline alloys

被引:11
作者
Gupta, Shalabh [1 ]
Ray, Asok [1 ]
Keller, Eric [1 ]
机构
[1] Penn State Univ, Mech Engn Dept, University Pk, PA 16802 USA
关键词
symbolic time series analysis; anomaly detection; fatigue damage;
D O I
10.1088/0957-0233/17/7/040
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper presents the concept and experimental validation of an analytical tool for fatigue damage monitoring in polycrystalline alloys. Ultrasonic signals are utilized for early detection of fatigue damage during the crack initiation period. Small microstructural changes occurring inside the material during the initial stages of fatigue damage cause attenuation and distortion of transmitted waves at the receiver end. The anomaly detection algorithm is based on time series analysis of ultrasonic data and is built upon the principles of symbolic dynamics, information theory and statistical signal processing. Experiments have been conducted for both constant amplitude and block loading of 7075-T6 aluminium alloy compact specimens on a special-purpose test apparatus that is equipped with ultrasonics sensors and a travelling optical microscope for fatigue damage monitoring.
引用
收藏
页码:1963 / 1973
页数:11
相关论文
共 38 条
[31]   Symbolic dynamic analysis of complex systems for anomaly detection [J].
Ray, A .
SIGNAL PROCESSING, 2004, 84 (07) :1115-1130
[32]   Signed real measure of regular languages for discrete event supervisory control [J].
Ray, A .
INTERNATIONAL JOURNAL OF CONTROL, 2005, 78 (12) :949-967
[33]   In situ ultrasonic monitoring of surface fatigue crack initiation and growth from surface cavity [J].
Rokhlin, SI ;
Kim, JY .
INTERNATIONAL JOURNAL OF FATIGUE, 2003, 25 (01) :41-49
[34]  
ROSE J, 2004, ULTRASONIC WAVES MED
[35]  
Sobczyk K, 1992, RANDOM FATIGUE DATA
[36]  
Suresh S., 2003, FATIGUE MAT
[37]   On-line monitoring of fatigue cracks using ultrasonic surface waves [J].
Vanlanduit, S ;
Guillaume, P ;
Van der Linden, G .
NDT & E INTERNATIONAL, 2003, 36 (08) :601-607
[38]   MWM eddy-current arrays for crack initiation and growth monitoring [J].
Zilberstein, V ;
Walrath, K ;
Grundy, D ;
Schlicker, D ;
Goldfine, N ;
Abramovici, E ;
Yentzer, T .
INTERNATIONAL JOURNAL OF FATIGUE, 2003, 25 (9-11) :1147-1155