Efficacy and compatibility with mass spectrometry of methods for elution of proteins from sodium dodecyl sulfate-polyacrylamide gels and polyvinyldifluoride membranes

被引:21
作者
Jorgensen, CS
Jagd, M
Sorensen, BK
McGuire, J
Barkholt, V
Hojrup, P
Houen, G [1 ]
机构
[1] Statens Serum Inst, Dept Res & Dev, DK-2300 Copenhagen, Denmark
[2] Ciphergen Biosyst, Copenhagen, Denmark
[3] Tech Univ Denmark, Bioctr, DK-2800 Lyngby, Denmark
[4] Univ So Denmark, Inst Biochem & Mol Biol, Odense, Denmark
关键词
protein elution; sodium dodecyl sulfate-polyacrylamide gels; polyvinyldifluoride membranes; mass spectrometry;
D O I
10.1016/j.ab.2004.03.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The resolving power of sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) combined with isoelectric focusing in two-dimensional gel electrophoresis has made it one of the most important techniques for resolving complex mixtures, and it is of great importance for proteome mapping projects. As a result of this, methods for postelectrophoretic protein characterization are of Great interest as exemplified by in situ protease digestion combined with mass spectrometry (MS), which is the method of choice for identification of proteins. In this study we have developed and compared methods for recovering intact proteins from polyacrylamide gels and electroblotting membranes to define efficient methods compatible with MS. These methods complement in situ digestion protocols and allow determination of the molecular mass of whole proteins separated by SDS-PAGE. Passive elution of proteins from SDS-PAGE gels was efficient only in the presence of SDS, whereas electroelution was achieved using butTers without SDS. Surface-enhanced laser desorption/ionization MS (SELDI-MS) analysis of proteins eluted in the presence of SIDS was possible using ion exchange ProteinChip arrays for concentration of sample and removal of SDS. Comparison of different electroblotting methods verified that the different membranes and buffers were equally efficient for transfer of proteins in the range 20-100 kDa. Elution front polyvinyldifluoride membranes was most efficient using either concentrated Solutions of trifluoroacetic acid (TFA) or combinations of 8 M urea and 1% Triton X-100, 1% Tween 20, or 40% isopropanol. The same result was obtained using nitrocellulose membranes, except that these were incompatible with organic solvent and TFA. Elution by TFA was compatible with matrix-assisted laser desorption/ionization MS (MALDI-MS) but was complicated by a high degree of trifluoroacetylation of the proteins. Alternatively, elution by 8 M urea + 1% Triton X-100, 1% Tween 20, or 40% isopropanol was compatible with both SELDI-MS and MALDI-MS. Eluted proteins were identified in MS experiments by intact mass determination, by peptide mapping, and by MS/MS analysis. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:87 / 97
页数:11
相关论文
共 42 条
[1]   SEQUENCE-ANALYSIS OF PROTEINS SEPARATED BY POLYACRYLAMIDE-GEL ELECTROPHORESIS - TOWARDS AN INTEGRATED PROTEIN DATABASE [J].
AEBERSOLD, R ;
LEAVITT, J .
ELECTROPHORESIS, 1990, 11 (07) :517-527
[2]   INTERNAL AMINO-ACID SEQUENCE-ANALYSIS OF PROTEINS SEPARATED BY ONE-DIMENSIONAL OR TWO-DIMENSIONAL GEL-ELECTROPHORESIS AFTER INSITU PROTEASE DIGESTION ON NITROCELLULOSE [J].
AEBERSOLD, RH ;
LEAVITT, J ;
SAAVEDRA, RA ;
HOOD, LE ;
KENT, SBH .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1987, 84 (20) :6970-6974
[3]   AMINO-ACID ANALYSIS - DETERMINATION OF CYSTEINE PLUS HALF-CYSTINE IN PROTEINS AFTER HYDROCHLORIC-ACID HYDROLYSIS WITH A DISULFIDE COMPOUND AS ADDITIVE [J].
BARKHOLT, V ;
JENSEN, AL .
ANALYTICAL BIOCHEMISTRY, 1989, 177 (02) :318-322
[4]   High-efficiency blotting of proteins of diverse sizes following sodium dodecyl sulfate-polyacrylamide gel electrophoresis [J].
Bolt, MW ;
Mahoney, PA .
ANALYTICAL BIOCHEMISTRY, 1997, 247 (02) :185-192
[5]  
CLEVELAND DW, 1977, J BIOL CHEM, V252, P1102
[7]   SODIUM DODECYL-SULFATE GEL-ELECTROPHORESIS - STAINING OF POLYPEPTIDES USING HEAVY-METAL SALTS [J].
DZANDU, JK ;
JOHNSON, JF ;
WISE, GE .
ANALYTICAL BIOCHEMISTRY, 1988, 174 (01) :157-167
[8]   INTERNAL PROTEIN-SEQUENCE ANALYSIS - ENZYMATIC DIGESTION FOR LESS THAN 10 MU-G OF PROTEIN-BOUND TO POLYVINYLIDENE DIFLUORIDE OR NITROCELLULOSE MEMBRANES [J].
FERNANDEZ, J ;
DEMOTT, M ;
ATHERTON, D ;
MISCHE, SM .
ANALYTICAL BIOCHEMISTRY, 1992, 201 (02) :255-264
[9]   PROTEIN BLOTTING - PRINCIPLES AND APPLICATIONS [J].
GERSHONI, JM ;
PALADE, GE .
ANALYTICAL BIOCHEMISTRY, 1983, 131 (01) :1-15
[10]   Improved electrophoresis and transfer of picogram amounts of protein with hemoglobin [J].
Gillespie, PG ;
Gillespie, SKH .
ANALYTICAL BIOCHEMISTRY, 1997, 246 (02) :239-245