A prototype point-of-use assay for measuring heavy metal contamination in water using time as a quantitative readout

被引:77
作者
Lewis, Gregory G. [1 ]
Robbins, Jessica S. [1 ]
Phillips, Scott T. [1 ]
机构
[1] Penn State Univ, University Pk, PA 16802 USA
关键词
IMMUNOCHROMATOGRAPHIC ASSAY; COLORIMETRIC DETECTION; SIGNAL AMPLIFICATION; MICROFLUIDIC DEVICES; ROOM-TEMPERATURE; ONE-STEP; DNA; SYSTEM; DNAZYME; ANALYTE;
D O I
10.1039/c3cc47698g
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This Communication describes a prototype quantitative paper-based assay that simultaneously measures the levels of Pb2+ and Hg2+ in water. The assay requires only measurements of time to yield a quantitative readout, and the results are independent of sample volume, humidity, and sample viscosity.
引用
收藏
页码:5352 / 5354
页数:3
相关论文
共 31 条
[1]   Hybrid Nanoparticle-Liposome Detection of Phospholipase Activity [J].
Aili, Daniel ;
Mager, Morgan ;
Roche, David ;
Stevens, Molly M. .
NANO LETTERS, 2011, 11 (04) :1401-1405
[2]  
ALLEN MP, 1990, CLIN CHEM, V36, P1591
[3]  
[Anonymous], 2018, Guidelines for Drinking Water Quality
[4]   Immobilization of nonviral vectors during the freezing step of lyophilization [J].
Armstrong, TK ;
Anchordoquy, TJ .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2004, 93 (11) :2698-2709
[5]   A Two-Component Small Molecule System for Activity-Based Detection and Signal Amplification: Application to the Visual Detection of Threshold Levels of Pd(II) [J].
Baker, Matthew S. ;
Phillips, Scott T. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (14) :5170-5173
[6]   Chain and conformation stability of solid-state DNA: implications for room temperature storage [J].
Bonnet, Jacques ;
Colotte, Marthe ;
Coudy, Delphine ;
Couallier, Vincent ;
Portier, Joseph ;
Morin, Benedicte ;
Tuffet, Sophie .
NUCLEIC ACIDS RESEARCH, 2010, 38 (05) :1531-1546
[7]   Simple, distance-based measurement for paper analytical devices [J].
Cate, David M. ;
Dungchai, Wijitar ;
Cunningham, Josephine C. ;
Volckens, John ;
Henry, Charles S. .
LAB ON A CHIP, 2013, 13 (12) :2397-2404
[8]   "Flow Valve" Microfluidic Devices for Simple, Detectorless, and Label-Free Analyte Quantitation [J].
Chatterjee, Debolina ;
Mansfield, Danielle S. ;
Anderson, Neil G. ;
Subedi, Sudeep ;
Woolley, Adam T. .
ANALYTICAL CHEMISTRY, 2012, 84 (16) :7057-7063
[9]   Semiquantitative, bar code version of immunochromatographic assay system for human serum albumin as model analyte [J].
Cho, JH ;
Paek, SH .
BIOTECHNOLOGY AND BIOENGINEERING, 2001, 75 (06) :725-732
[10]   Determination of aerosol oxidative activity using silver nanoparticle aggregation on paper-based analytical devices [J].
Dungchai, Wijitar ;
Sameenoi, Yupaporn ;
Chailapakul, Orawon ;
Volckens, John ;
Henry, Charles S. .
ANALYST, 2013, 138 (22) :6766-6773