Interfacing flow injection with capillary electrophoresis and inductively coupled plasma mass spectrometry for Cr speciation in water samples

被引:20
作者
Giné, MF
Gervasio, APG
Lavorante, AF
Miranda, CES
Carrilho, E
机构
[1] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, Brazil
[2] USP, Inst Quim Sao Carlos, BR-13560970 Sao Carlos, SP, Brazil
关键词
D O I
10.1039/b202387c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A hyphenated system coupling flow injection (FI), capillary electrophoresis (CE) and inductively coupled plasma mass spectrometry (ICP-MS) is proposed. Two interfaces were developed in order to couple all three systems: the first to couple FI to CE and the second to couple CE to ICP-MS. The first interface was a chamber with micro channels connecting the FI system to the electrophoresis capillary inlet. The capillary outlet was coupled to a concentric nebulizer in the ICP-MS by using the second interface with an electrolyte sheath flow and grounding electrode. Sample aliquots were sequentially introduced by the FI system with a few nanolitres being electrokinetically injected into the electrophoresis capillary in a reproducible manner. The system performed analysis of a continuous sequence of samples with no interruption of the applied voltage during sample replacement or column conditioning. The feasibility of this system was evaluated for Cr speciation. The separation time was improved by forming an anionic complex between Cr(III) and DTPA. Therefore, the analysis of both Cr species, Cr(III)-DTPA(2-) and CrO42-, attained compatible sample processing between CE and the interfaced techniques FI and ICP-MS. The anionic chromium species were separated in less than 2 min by applying 20 kV in a phosphate electrolyte with TTAOH (tetradecyltrimethylammonium hydroxide) as electroosmotic flow modifier adjusted to pH 8. The transient signals from both species monitored at m/z 53 were characterized by excellent resolution and precision. Peaks obtained using Cr(VI) and Cr(III) standard solutions with concentration ranging from 50 to 200 mug L-1 presented good correlation.
引用
收藏
页码:736 / 738
页数:3
相关论文
共 16 条
[1]   Interface for capillary electrophoresis coupled with inductively coupled plasma atomic emission spectrometry [J].
Chan, YY ;
Chan, WT .
JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) :141-149
[2]   Combination of flow injection with capillary electrophoresis .1. The basic system [J].
Fang, ZL ;
Liu, ZS ;
Shen, Q .
ANALYTICA CHIMICA ACTA, 1997, 346 (02) :135-143
[3]   Combination of flow injection with capillary electrophoresis - Part 7. Microchip capillary electrophoresis system with flow injection sample introduction and amperometric detection [J].
Fu, CG ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 2000, 422 (01) :71-79
[4]   Simultaneous determination of chromium(III) and Chromium(VI) in aqueous solution by capillary electrophoresis with on-column UV-VIS detection [J].
Jung, GY ;
Kim, YS ;
Lim, HB .
ANALYTICAL SCIENCES, 1997, 13 (03) :463-467
[5]   Effect of laminar flow in capillary electrophoresis: Model and experimental results on controlling analysis time and resolution with inductively coupled plasma mass spectrometry detection [J].
Kinzer, JA ;
Olesik, JW ;
Olesik, SV .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3250-3257
[6]   Interfacing of flow injection pre-treatment systems with capillary electrophoresis [J].
Kuban, P ;
Karlberg, B .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1998, 17 (01) :34-41
[7]   New interface for coupling flow-injection and capillary electrophoresis [J].
Kuban, P ;
Engstrom, A ;
Olsson, JC ;
Thorsen, G ;
Tryzell, R ;
Karlberg, B .
ANALYTICA CHIMICA ACTA, 1997, 337 (02) :117-124
[8]   On-line flow sample stacking in a flow injection analysis-capillary electrophoresis system:: 2000-fold enhancement of detection sensitivity for priority phenol pollutants [J].
Kuban, P ;
Berg, M ;
García, C ;
Karlberg, B .
JOURNAL OF CHROMATOGRAPHY A, 2001, 912 (01) :163-170
[9]   Flow injection analysis capillary electrophoresis system with hydrodynamic injection [J].
Kuban, P ;
Pirmohammadi, R ;
Karlberg, B .
ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) :55-62
[10]   Two simple interface designs for capillary electrophoresis inductively coupled plasma mass spectrometry [J].
Majidi, V ;
Miller-Ihli, NJ .
ANALYST, 1998, 123 (05) :803-808