Phosphate sensing system using pyruvate oxidase and chemiluminescence detection

被引:35
作者
Ikebukuro, K
Wakamura, H
Karube, I
Kubo, I
Inagawa, M
Sugawara, T
Arikawa, Y
Suzuki, M
Takeuchi, T
机构
[1] UNIV TOKYO,ADV SCI & TECHNOL RES CTR,MEGURO KU,TOKYO 153,JAPAN
[2] SOKA UNIV,FAC ENGN,DEPT BIOENGN,HACHIOJI,TOKYO 192,JAPAN
[3] JAPAN WOMENS UNIV,FAC SCI,DEPT CHEM & BIOL SCI,BUNKYO KU,TOKYO 112,JAPAN
[4] KYUSHU INST TECHNOL,FAC COMP SCI & SYST ENGN,DEPT BIOCHEM ENGN SCI,IIZUKA,FUKUOKA 820,JAPAN
[5] HIROSHIMA CITY UNIV,FAC INFORMAT SCI,ASANAMI KU,HIROSHIMA 73113,JAPAN
关键词
phosphate; luminol; chemiluminescence; pyruvate oxidase; flow injection analysis;
D O I
10.1016/0956-5663(96)87655-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A flow injection phosphate analysis system based on an enzymic reaction and a subsequent luminol chemiluminescence reaction has been developed. The system consists of an immobilized pyruvate oxidase column, mixing chamber for the chemiluminescent reaction and a photomultiplier. The H2O2 generated by the reaction of phosphate and pyruvate oxidase then reacts with luminol and horseradish peroxidase and the consequent chemiluminescence is detected using a photomultiplier. This system is capable of the rapid determination of phosphate, the time required for one measurement cycle being approximately 3 min. A linear response was observed from 4.8 to 160 mu M phosphate. (C) 1996 Elsevier Science Limited.
引用
收藏
页码:959 / 965
页数:7
相关论文
共 15 条
[1]  
*APHA AWWA WPCF, 1976, STAND METH EX WAT WA
[2]   PHOSPHATE-SENSITIVE ENZYME ELECTRODE - A POTENTIAL SENSOR FOR ENVIRONMENT CONTROL [J].
DURSO, EM ;
COULET, PR .
ANALYTICA CHIMICA ACTA, 1990, 239 (01) :1-5
[3]   PHOSPHATE-SELECTIVE ELECTRODE BASED ON IMMOBILIZED ALKALINE-PHOSPHATASE AND GLUCOSE OXIDASE [J].
GUILBAULT, GG ;
NANJO, M .
ANALYTICA CHIMICA ACTA, 1975, 78 (01) :69-80
[4]  
KREBS CJ, 1972, ECOLOGY EXPT ANAL DI, P454
[5]   CHEMI-LUMINESCENT AND BIOLUMINESCENT METHODS IN ANALYTICAL-CHEMISTRY - A REVIEW [J].
KRICKA, LJ ;
THORPE, GHG .
ANALYST, 1983, 108 (1292) :1274-1296
[6]   PHOSPHATE SENSOR COMPOSED FROM IMMOBILIZED PYRUVATE OXIDASE AND AN OXYGEN-ELECTRODE [J].
KUBO, I ;
INAGAWA, M ;
SUGAWARA, T ;
ARIKAWA, Y ;
KARUBE, I .
ANALYTICAL LETTERS, 1991, 24 (10) :1711-1727
[7]  
LOWRY OH, 1946, J BIOL CHEM, V162, P421
[8]   SINGLE-ENZYME-BASED AMPEROMETRIC ASSAY FOR PHOSPHATE ION [J].
NGO, TT .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1986, 13 (02) :127-131
[9]  
RINDI Y, 1961, BIOCHEM J, V78, P602
[10]  
THORPE GHG, 1985, CLIN CHEM, V31, P1335