Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiography for the detection of patent foramen ovale in stroke patients

被引:61
作者
Devuyst, G [1 ]
Despland, PA [1 ]
Bogousslavsky, J [1 ]
Jeanrenaud, X [1 ]
机构
[1] CHU VAUDOIS,LAUSANNE,SWITZERLAND
关键词
patent foramen ovale; contrast transcranial Doppler ultrasound; contrast transesophageal echocardiography; complementarity;
D O I
10.1159/000112897
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
All studies concerning the detection of patent foramen ovale (PFO) have compared transthoracic or transesophageal echocardiography (c-TEE) to transcranial Doppler ultrasound after contrast injection (c-TCD), but combining both techniques in the search of PFO has received no consideration. Our study aims to substantiate this claim in 37 patients with cryptogenic stroke. It includes two protocols for the detection of PFO to assess the complementarity of c-TCD and c-TEE performed simultaneously or separately. Firstly, we used a standardized protocol, performing c-TCD alone. Secondly, we used a standardized and a simultaneous protocol which associated c-TCD with c-TEE. When c-TCD and/or c-TEE found right-to-left shunts, they were classified as: minimal, intermediate and massive. c-TCD revealed all PFO detected by c-TEE in 24 patients out of 37 (65%). Furthermore, c-TCD was positive for a PFO in 5 other patients whereas c-TEE was negative. The degree of right-to-left interatrial shunting varied according to the protocol: c-TCD performed alone found 15 massive, 4 intermediate and 5 minimal shunts whereas 10, 9 and 5, respectively, were detected by c-TCD when it was combined with c-TEE. In contrast, c-TEE revealed 8 massive, 8 intermediate and 8 minimal shunts. c-TCD can identify minimal shunts missed by c-TEE and could be more relevant to detect massive shunts, particularly when not performed simultaneously with c-TEE because no sedation is required for c-TCD alone as opposed to c-TEE: thus patients are more cooperative and produce a better Valsalva strain. c-TEE confirms pulmonary shunts suspected by c-TCD and determines the morphologic characteristics of the interatrial septum. While previous studies opposed c-TEE against c-TCD for the detection of a PFO, we think that both techniques are complementary and that it is interesting to associate them, particularly when they are deferred, to increase the ability of detecting PFO and to specify the degree of right-to-left shunting.
引用
收藏
页码:21 / 25
页数:5
相关论文
共 16 条
  • [1] VALIDATION OF TRANSCRANIAL DOPPLER SONOGRAPHY IN THE ASSESSMENT OF PATENT FORAMEN OVALE
    ANZOLA, GP
    RENALDINI, E
    MAGONI, M
    COSTA, A
    COBELLI, M
    GUINDANI, M
    [J]. CEREBROVASCULAR DISEASES, 1995, 5 (03) : 194 - 198
  • [2] Stroke recurrence in patients with patent foramen ovale: The Lausanne Study
    Bogousslavsky, J
    Garazi, S
    Jeanrenaud, X
    Aebischer, N
    VanMelle, G
    [J]. NEUROLOGY, 1996, 46 (05) : 1301 - 1305
  • [3] Prognosis after stroke followed by surgical closure of patent foramen ovale: A prospective follow-up study with brain MRI and simultaneous transesophageal and transcranial Doppler ultrasound
    Devuyst, G
    Bogousslavsky, J
    Ruchat, P
    Jeanrenaud, X
    Despland, AP
    Regli, F
    Aebischer, N
    Karpuz, HM
    Castillo, V
    Guffi, M
    Sadeghi, H
    [J]. NEUROLOGY, 1996, 47 (05) : 1162 - 1166
  • [4] COMPARISON OF DIAGNOSTIC-TECHNIQUES FOR THE DETECTION OF A PATENT FORAMEN OVALE IN STROKE PATIENTS
    DITULLIO, M
    SACCO, RL
    VENKETASUBRAMANIAN, N
    SHERMAN, D
    MOHR, JP
    HOMMA, S
    [J]. STROKE, 1993, 24 (07) : 1020 - 1024
  • [5] CONTRAST ECHOCARDIOGRAPHIC VISUALIZATION OF COUGH-INDUCED RIGHT TO LEFT SHUNT THROUGH A PATENT FORAMEN OVALE
    DUBOURG, O
    BOURDARIAS, JP
    FARCOT, JC
    GUERET, P
    TERDJMAN, M
    FERRIER, A
    RIGAUD, M
    BARDET, JC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (03) : 587 - 594
  • [6] CHARACTERISTICS OF PATENT FORAMEN OVALE ASSOCIATED WITH CRYPTOGENIC STROKE - A BIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHIC STUDY
    HOMMA, S
    DITULLIO, MR
    SACCO, RL
    MIHALATOS, D
    MANDRI, GL
    MOHR, JP
    [J]. STROKE, 1994, 25 (03) : 582 - 586
  • [7] A COMPARISON OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY AND TRANSCRANIAL DOPPLER SONOGRAPHY WITH CONTRAST-MEDIUM FOR DETECTION OF PATENT FORAMEN OVALE
    JAUSS, M
    KAPS, M
    KEBERLE, M
    HABERBOSCH, W
    DORNDORF, W
    [J]. STROKE, 1994, 25 (06) : 1265 - 1267
  • [8] COMPARISON OF TRANSCRANIAL CONTRAST DOPPLER SONOGRAPHY AND TRANSESOPHAGEAL CONTRAST ECHOCARDIOGRAPHY FOR THE DETECTION OF PATENT FORAMEN OVALE IN YOUNG STROKE PATIENTS
    JOB, FP
    RINGELSTEIN, EB
    GRAFEN, Y
    FLACHSKAMPF, FA
    DOHERTY, C
    STOCKMANNS, A
    HANRATH, P
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (04) : 381 - 384
  • [9] DETECTION OF PATENT FORAMEN OVALE BY TRANSCRANIAL CONTRAST DOPPLER ULTRASOUND
    KARNIK, R
    STOLLBERGER, C
    VALENTIN, A
    WINKLER, WB
    SLANY, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (05) : 560 - 562
  • [10] TRANSESOPHAGEAL ECHOCARDIOGRAPHY AND CONTRAST-TCD IN THE DETECTION OF A PATENT FORAMEN OVALE - EXPERIENCES WITH 111 PATIENTS
    KLOTZSCH, C
    JANSSEN, G
    BERLIT, P
    [J]. NEUROLOGY, 1994, 44 (09) : 1603 - 1606