Sweeteners determination in table top formulations using FT-Raman spectrometry and chemometric analysis

被引:42
作者
Armenta, S [1 ]
Garrigues, S [1 ]
de la Guardia, M [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Burjassot, Valencia, Spain
关键词
sweeteners; sodium saccharin; sodium cyclamate; Raman; powder analysis;
D O I
10.1016/j.aca.2004.05.077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A partial least squares (PLS) Fourier transform Raman spectrometry procedure based on the measurement of solid samples contained inside standard glass vials, has been developed for direct and reagent-free determination of sodium saccharin and sodium cyclamate in table top sweeteners. A classical 2(2) design for standards was used for calibration, but this system provides accuracy errors higher than 13% w/w for the analysis of samples containing glucose monohydrate. So, an extended model incorporating glucose monohydrate (2(3) standards) was assayed for the determination of sodium saccharin and sodium cyclamate in all the samples. Mean centering spectra data pre-treatment has been employed to eliminate common spectral information and root mean square error of calibration (RMSEC) of 0.0064 and 0.0596 was obtained for sodium saccharin and sodium cyclamate, respectively. A mean accuracy error of the order of 1.1 and 1.9% w/w was achieved for sodium saccharin and sodium cyclamate, in the validation of the method using actual table top samples, being lower than those obtained using an external monoparametric calibration. FT-Raman provides a fast alternative to the chromatographic method for the determination of the sweeteners with a three times higher sampling throughput than that obtained in HPLC. On the other hand, FT-Raman offers an environmentally friendly methodology which eliminates the use of solvents. Furthermore, the stability of samples and standards into chromatographic standard glass vials allows their storage for future analysis thus avoiding completely the waste generation. (C) 2004 Elsevier B.V. All fights reserved.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 11 条
[1]   Ion selective electrode for potentiometric determination of saccharin using a thin film of silsesquioxane 3-n-propylpyridinium chloride polymer coated-graphite rod [J].
Alfaya, RVS ;
Alfaya, AAS ;
Gushikem, Y ;
Rath, S .
ANALYTICAL LETTERS, 2000, 33 (14) :2859-2871
[2]  
ARMENTA S, ANAL CHIM ACTA
[3]   Simultaneous determination of antioxidants, preservatives and sweeteners permitted as additives in food by mixed micellar electrokinetic chromatography [J].
Boyce, MC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 847 (1-2) :369-375
[4]   Flow-injection spectrophotometric determination of cyclamate in sweetener products with sodium 1,2-naphthoquinone-4 sulfonate [J].
Cabero, C ;
Saurina, J ;
Hernández-Cassou, S .
ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) :307-313
[5]   DETERMINATION OF ADDITIVES IN WINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CALULL, M ;
MARCE, RM ;
SANCHEZ, G ;
BORRULL, F .
JOURNAL OF CHROMATOGRAPHY, 1992, 607 (02) :339-347
[6]   Separation and determination of four artificial sweeteners and citric acid by high-performance anion-exchange chromatography [J].
Chen, QC ;
Mou, SF ;
Liu, KN ;
Yang, ZY ;
Ni, ZM .
JOURNAL OF CHROMATOGRAPHY A, 1997, 771 (1-2) :135-143
[7]  
LINVIEN D, 1991, INRARED RAMAN CHARAC
[8]  
*MACH HAG, 2000, A1835 MACH, P2
[9]  
Nikolelis DP, 2000, ELECTROANAL, V12, P786, DOI 10.1002/1521-4109(200006)12:10<786::AID-ELAN786>3.0.CO
[10]  
2-3