Technical principles of dual energy x-ray absorptiometry

被引:174
作者
Blake, GM
Fogelman, I
机构
[1] Department of Nuclear Medicine, Guy's Hospital, London SE1 9RT, St Thomas St
关键词
D O I
10.1016/S0001-2998(97)80025-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Since its introduction nearly ten years ago, dual-energy x-ray absorptiometry (DXA) has become the single most widely used technique for performing bone densitometry studies. One reason for its popularity is the ability of DXA systems to measure bone mineral density (BMD) in the spine and proximal femur, the two most common sites for osteoporotic fractures. Other advantages of DXA include the exceptionally low radiation dose to patients, short scan times, high resolution images, good precision and inherent stability of calibration. For these reasons DXA scans are widely used to diagnose osteoporosis, assist making decisions in treatment, and as a follow-up response to therapy. Another important application has been the use of DXA in many clinical trials of new treatments for osteoporosis. Since the first generation pencil beam DXA systems became available, the most significant technical innovation has been the introduction of fan beam systems with shorter scan times, increased patient throughput, and improved image quality. New clinical applications include the measurement of lateral spine and total body BMD, body composition, and vertebral morphometry. Despite these advances, posteroanterior (PA) spine and proximal femur scans remain the most widely used application because of their utility in treatment decisions and monitoring response to therapy. Copyright (C) 1997 by W.B. Saunders Company.
引用
收藏
页码:210 / 228
页数:19
相关论文
共 84 条
  • [1] BLACK DM, 1992, J BONE MINER RES, V7, P633
  • [2] Randomised trial of effect of alendronate on risk of fracture in women with existing vertebral fractures
    Black, DM
    Cummings, SR
    Karpf, DB
    Cauley, JA
    Thompson, DE
    Nevitt, MC
    Bauer, DC
    Genant, HK
    Haskell, WL
    Marcus, R
    Ott, SM
    Torner, JC
    Quandt, SA
    Reiss, TF
    Ensrud, KE
    [J]. LANCET, 1996, 348 (9041) : 1535 - 1541
  • [3] Vertebral morphometry studies using dual-energy x-ray absorptiometry
    Blake, GM
    Rea, JA
    Fogelman, I
    [J]. SEMINARS IN NUCLEAR MEDICINE, 1997, 27 (03) : 276 - 290
  • [4] DUAL X-RAY ABSORPTIOMETRY - A COMPARISON BETWEEN FAN-BEAM AND PENCIL BEAM SCANS
    BLAKE, GM
    PARKER, JC
    BUXTON, FMA
    FOGELMAN, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (790) : 902 - 906
  • [5] DUAL X-RAY ABSORPTIOMETRY OF THE LUMBAR SPINE - THE PRECISION OF PAIRED ANTEROPOSTERIOR/LATERAL STUDIES
    BLAKE, GM
    JAGATHESAN, T
    HERD, RJM
    FOGELMAN, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (799) : 624 - 630
  • [6] Replacing DXA scanners: Cross-calibration with phantoms may be misleading
    Blake, GM
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1996, 59 (01) : 1 - 5
  • [7] A longitudinal study of supine lateral DXA of the lumbar spine: A comparison with posteroanterior spine, hip and total-body DXA
    Blake, GM
    Herd, RJM
    Fogelman, I
    [J]. OSTEOPOROSIS INTERNATIONAL, 1996, 6 (06) : 462 - 470
  • [8] DUAL ENERGY X-RAY ABSORPTIOMETRY - THE EFFECTS OF BEAM HARDENING ON BONE-DENSITY MEASUREMENTS
    BLAKE, GM
    MCKEENEY, DB
    CHHAYA, SC
    RYAN, PJ
    FOGELMAN, I
    [J]. MEDICAL PHYSICS, 1992, 19 (02) : 459 - 465
  • [9] BLAKE GM, 1996, J BONE MINER RES S1, V11, pS157
  • [10] Cross-calibration of a fan-beam X-ray densitometer with a pencil-beam system
    Bouyoucef, SE
    Cullum, ID
    Jell, P
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (822) : 522 - 531