In vitro comparison of nasal continuous positive airway pressure devices for neonates

被引:58
作者
De Paoli, AG
Morley, CJ
Davis, PG
Lau, R
Hingeley, E
机构
[1] Royal Hosp Women, Dept Neonatol, Serv Neonatol, Carlton, Vic 3053, Australia
[2] Royal Hosp Women, Dept Biomed Engn, Carlton, Vic 3053, Australia
来源
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION | 2002年 / 87卷 / 01期
关键词
D O I
10.1136/fn.87.1.F42
中图分类号
R72 [儿科学];
学科分类号
100202 [儿科学];
摘要
Objective: To compare the resistance in vitro of different devices used for the delivery of nasal continuous positive airway pressure (NCPAP) in neonates. Design: Flows of 4-8 litres/min were passed through a selection of neonatal NCPAP devices (single prong, Duotube, Argyle prong, Hudson prong, Infant Flow Driver), and the resultant fall in pressure measured using a calibrated pressure transducer. Results: The decrease in pressure (cm H2O) for each device (size in parentheses) at a constant flow of 6 litres/min was: Duotube: (2.5), 2 1; (3.0), 6.2; (3.5), 2.3; single prong: (2.5), 4.4; (3.0), 2.1; (3.5), 1.2; Argyle prong: (XS), 3.6; (S), 1.9; (L), 1.5; Hudson prong: (0), 3.1; (1), 1.8; (2), 0.6; (3), 0.4; (4), 0.3; Infant Flow Driver: (small), 0.3; (medium), -0.3; (large), -0.5. Conclusions: A large variation in the potential fall in pressure may occur in the clinical setting. Devices with short double prongs had the lowest resistance to flow. These results have implications in the selection of the optimal device/s for clinical application and for future comparisons in randomised trials of NCPAP in neonates.
引用
收藏
页码:F42 / F45
页数:4
相关论文
共 26 条
[1]
Infant flow driver or single prong nasal continuous positive airway pressure: short-term physiological effects [J].
Ahluwalia, JS ;
White, DK ;
Morley, CJ .
ACTA PAEDIATRICA, 1998, 87 (03) :325-327
[2]
TWIN NASAL CANNULA FOR ADMINISTRATION OF CONTINUOUS POSITIVE AIRWAY PRESSURE TO NEWBORN-INFANTS [J].
CALIUMIP.G ;
AGOSTINO, R ;
ORZALESI, M ;
NODARI, S ;
MARZETTI, G ;
SAVIGNONI, PG ;
BUCCI, G .
ARCHIVES OF DISEASE IN CHILDHOOD, 1974, 49 (03) :228-230
[3]
Lung recruitment and breathing pattern during variable versus continuous flow nasal continuous positive airway pressure in premature infants: An evaluation of three devices [J].
Courtney, SE ;
Pyon, KH ;
Saslow, JG ;
Arnold, GK ;
Pandit, PB ;
Habib, RH .
PEDIATRICS, 2001, 107 (02) :304-308
[4]
A randomised controlled trial of two methods of delivering nasal continuous positive airway pressure after extubation to infants weighing less than 1000 g: binasal (Hudson) versus single nasal prongs [J].
Davis, P ;
Davies, M ;
Faber, B .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2001, 85 (02) :F82-F85
[5]
DAVIS PG, 2001, COCHRANE LIB
[6]
CONTINUOUS POSITIVE AIRWAY PRESSURE VIA A SINGLE NASAL CATHETER IN PRETERM INFANTS [J].
FIELD, D ;
VYAS, H ;
MILNER, AD ;
HOPKIN, IE .
EARLY HUMAN DEVELOPMENT, 1985, 11 (3-4) :275-280
[7]
GOLDMAN SL, 1979, PEDIATRICS, V64, P160
[8]
TREATMENT OF IDIOPATHIC RESPIRATORY-DISTRESS SYNDROME WITH CONTINUOUS POSITIVE AIRWAY PRESSURE [J].
GREGORY, GA ;
KITTERMAN, JA ;
PHIBBS, RH ;
TOOLEY, WH ;
HAMILTON, WK .
NEW ENGLAND JOURNAL OF MEDICINE, 1971, 284 (24) :1333-+
[9]
*GROV MED LTD, 2001, SPECTR PHYSL SOFTW C
[10]
Estimation of inspiratory pressure drop in neonatal and pediatric endotracheal tubes [J].
Jarreau, PH ;
Louis, B ;
Dassieu, G ;
Desfrere, L ;
Blanchard, PW ;
Moriette, G ;
Isabey, D ;
Harf, A .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (01) :36-46