Development of an optimised, standard-compliant procedure to calculate sound transmission loss: design of transmission rooms

被引:18
作者
Papadopoulos, CI [1 ]
机构
[1] NTUA, Dept Naval Architecture & Marine Engn, Zografos 15773, Greece
关键词
D O I
10.1016/S0003-682X(02)00005-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A numerical procedure to estimate the transmission loss of sound insulating structures is proposed based upon the technology of acoustic measurements and standards. A virtual laboratory (VL), namely, a numerical representation of a real laboratory consisting of two reverberation rooms meeting certain sound field quality criteria is designed. VL is to be used for the numerical simulation of standardised measurements under predefined. controlled, acoustic conditions. In this paper, the design and optimisation of VL is investigated. The geometry of the transmission rooms is designed following first principles, in order for diffuse field conditions and sufficiently smooth primary mode distribution in the low frequency to be achieved, A finite element-based optimisation procedure, introduced by the author in previous work, is extended to arbitrarily shaped rooms. It is used to predict the appropriate local geometric modifications so as for improved mode distribution and smoother sound pressure fluctuations of the transmission rooms in the low-frequency range to be achieved and low-frequency measurement reproducibility and accuracy to be increased. Steady-state acoustic response analysis is performed in order to quantify the acoustic field quality of the virtual transmission rooms in the frequency range of measurements. A method to calculate the total absorption, A, of the receiving room is introduced by simulation of the reverberation time measurement procedure using Transient acoustic response analysis. The acoustic performance of VL is overall considered and is shown to meet in a sufficient degree, relative laboratory measurement standards in the frequency range of 100divided by704 Hz. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1003 / 1029
页数:27
相关论文
共 40 条
[11]  
*ELOT, 1978, 3701IX ELOT
[12]  
*ELOT EN, 1996, 20354 ELOT EN
[13]   Qualifying freefield and reverberation rooms for frequencies below 100 Hz [J].
Fuchs, HV ;
Zha, X ;
Pommerer, M .
APPLIED ACOUSTICS, 2000, 59 (04) :303-322
[14]   Noise barriers with reactive surfaces [J].
Fujiwara, K ;
Hothersall, DC ;
Kim, C .
APPLIED ACOUSTICS, 1998, 53 (04) :255-272
[15]  
GOMPERTS MC, 1974, ACUSTICA, V30, P320
[16]   New international standards for building and room acoustics [J].
Goydke, H .
APPLIED ACOUSTICS, 1997, 52 (3-4) :185-196
[17]  
GUY RW, 1981, ACUSTICA, V49, P323
[18]   An evaluation of the importance of surface diffusivity in concert halls [J].
Haan, CH ;
Fricke, FR .
APPLIED ACOUSTICS, 1997, 51 (01) :53-69
[19]  
HANSEN CH, 1991, P INT C NOIS CONTR E
[20]  
HAROUM MA, 1999, P 7 INT C CIV STRUCT