Modified pencil lead as a new fiber for solid-phase microextraction

被引:78
作者
Djozan, D [1 ]
Assadi, Y [1 ]
机构
[1] Univ Tabriz, Fac Chem, Dept Analyt Chem, Tabriz, Iran
关键词
gas chromatography; solid-phase microextraction; new fibers; pencil lead; PAH;
D O I
10.1365/s10337-004-0368-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The efficiency of modified pencil lead as a new fiber for solid-phase microextraction (SPME) has been investigated. Modified pencil lead fibers have been prepared by use of several activation processes, for example beating at 600 degreesC in the stream of inert gas (He), heating under reflux with concentrated H2SO4, fusing with NaOH at 400 degreesC, and activation at 600 degreesC with water vapor for 60 min. The fibers were used for extraction of trace amounts of polycyclic aromatic hydrocarbons (PAH) from aqueous samples. Monitoring of extracted compounds and quantitative analysis of model samples were performed by capillary GC-FID. The results obtained prove the suitability of the proposed fibers for sampling organic compounds from water. Effects on extraction efficiency of factors such as temperature, salting out, stirring speed, and exposure time were studied. Under optimum conditions and using one fiber for extraction of naphthalene as a typical compound, a relative standard deviation of 5.3% (n = 7) was achieved. The calibration plot was linear in the range 50-10,000 pg mL(-1) (r = 0.9997) and the detection limit was 25 pg mL(-1) (S/N = 3). This fiber is very stable at high temperature, inexpensive, and can be prepared simply.
引用
收藏
页码:313 / 317
页数:5
相关论文
共 22 条
[11]   Anodized aluminum wire as a solid-phase microextraction fiber [J].
Djozan, D ;
Assadi, Y ;
Haddadi, SH .
ANALYTICAL CHEMISTRY, 2001, 73 (16) :4054-4058
[12]   SOLVENTLESS DETERMINATION OF CAFFEINE IN BEVERAGES USING SOLID-PHASE MICROEXTRACTION WITH FUSED-SILICA FIBERS [J].
HAWTHORNE, SB ;
MILLER, DJ ;
PAWLISZYN, J ;
ARTHUR, CL .
JOURNAL OF CHROMATOGRAPHY, 1992, 603 (1-2) :185-191
[13]   Porous layer solid phase microextraction using silica banded phases [J].
Liu, Y ;
Shen, YF ;
Lee, ML .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :190-195
[14]  
Mangani F, 1995, CHROMATOGRAPHIA, V41, P678
[15]  
Moret S, 2002, J SEP SCI, V25, P96, DOI 10.1002/1615-9314(20020101)25:1/2<96::AID-JSSC96>3.0.CO
[16]  
2-5
[17]  
Pawliszyn J., 1997, SOLID PHASE MICROEXT
[18]   Quantitative analysis of polycyclic aromatic hydrocarbons in sewage sludge from wastewater treatment plants [J].
Pérez, S ;
Guillamón, M ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 2001, 938 (1-2) :57-65
[19]   UV-detection capillary electrophoresis for benzo[a]pyrene and pyrene following a two-step concentration system using homogeneous liquid-liquid extraction and a sweeping method [J].
Takagai, Y ;
Igarashi, S .
ANALYST, 2001, 126 (05) :551-552
[20]   Solid-phase microextraction determination of alcohol using pencil lead [J].
Tong, Z ;
Guanghan, L ;
Xin, Y .
ANALYTICAL LETTERS, 2001, 34 (04) :627-634