Large bore pulsed field magnetometer for characterizing permanent magnets

被引:14
作者
Grössinger, R
Wittig, E
Küpferling, M
Taraba, M
Reyne, G
Golovanov, C
Enzberg-Mahlke, B
Fernengel, W
Lethuillier, P
Dudding, J
机构
[1] Vienna Tech Univ, Inst Expt Phys, A-1040 Vienna, Austria
[2] Univ Ensieg LEG, St Martin Dheres, France
[3] Magnetfabr Schramberg, Schramberg Sulgen, Germany
[4] VAC, Hanau, Germany
[5] CNRS, Grenoble, France
[6] Hirst Magnet Instr, Cornwall, England
关键词
pulsed field magnetometer; permanent magnets;
D O I
10.1109/20.800725
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A large bore pulsed field hysteresigraph is described. The system shall be used for a fast quality control of industrial permanent magnets. It consists of a pulse magnet with a bore of 70 mm inner diameter and a maximum held of 10 T. The pulse duration can be varied between 4 and 15.7 ms. The system is calibrated within 1%.