1. The aim of the present study was to validate a telemetric blood pressure (BP) monitoring system against tail-cuff blood pressure in both adrenocorticotrophic hormone (ACTH)- and sham-treated rats. In the statistical analyses, we first tested whether there was a detectable effect on systolic blood pressure (SBP) of 10 days treatment with ACTH compared with saline. Second, we compared results of telemetered and tail-cuff measurements and, third, we developed a novel method for estimating the relative power of the two techniques. 2. Twenty-three male Sprague-Dawley rats were randomly divided into two groups: (i) ACTH (100 mug/kg per day, s.c.; n = 12) treated; or (ii) sham treated (0.9% saline, s.c.; n = 11). Systolic BP was measured by the telemetric system (sampled for 10 s every 2 min) continuously for 4 h (n = 16) or for 30 min (n = 23) and also by the indirect tail-cuff method daily (n = 23). Data were compared within and between groups; ordinary least products (OLP) regression analysis was then performed to test for bias between the two methods. Sample size/power estimations were also performed. 3. Adrenocorticotrophic hormone treatment raised telemetered SBP by 11 mmHg (P < 0.001) compared with 14 mmHg (P < 0.001) using the tail-cuff method. There was no fixed or proportional bias between the two methods of measurement, as shown by regression analysis. Power calculations indicate that a minimum sample size of six gives a power of telemetered to tail-cuff of 0.84/0.86 = 0.98. The power of 4 h versus 30 min BP measurements was 0.99/0.82 = 1.2. 4. Telemetry gave very similar results to the tail-cuff method. Telemetry allows for a longer period of measurement, giving greater power to the study so that fewer animals are needed.
引用
收藏
页码:831 / 835
页数:5
相关论文
共 14 条
[1]  
ADAMS MR, 1988, LAB ANIM SCI, V38, P279
[2]   A COMPARISON OF PROPOFOL WITH OTHER INJECTABLE ANESTHETICS IN A RAT MODEL FOR MEASURING CARDIOVASCULAR PARAMETERS [J].
BRAMMER, A ;
WEST, CD ;
ALLEN, SL .
LABORATORY ANIMALS, 1993, 27 (03) :250-257
[3]   A NEW METHOD FOR CONTINUOUS CHRONIC MEASUREMENT AND RECORDING OF BLOOD-PRESSURE, HEART-RATE AND ACTIVITY IN THE RAT VIA RADIOTELEMETRY [J].
BROCKWAY, BP ;
MILLS, PA ;
AZAR, SH .
CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1991, 13 (05) :885-895
[4]  
BUNAG RD, 1983, CLIN EXP HYPERTENS A, V5, P1659
[5]   VALIDATION IN AWAKE RATS OF A TAIL-CUFF METHOD FOR MEASURING SYSTOLIC PRESSURE [J].
BUNAG, RD .
JOURNAL OF APPLIED PHYSIOLOGY, 1973, 34 (02) :279-282
[6]  
GRUBER KA, 1989, AM J PHYSIOL, V256, pR1308, DOI 10.1152/ajpregu.1989.256.6.R1308
[7]  
LENTNER C, 1982, GEIGY SCI TABLES 2 I
[8]   Comparing methods of measurement [J].
Ludbrook, J .
CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1997, 24 (02) :193-203
[9]   REPEATED MEASUREMENTS AND MULTIPLE COMPARISONS IN CARDIOVASCULAR RESEARCH [J].
LUDBROOK, J .
CARDIOVASCULAR RESEARCH, 1994, 28 (03) :303-311
[10]  
MULLER KE, 1989, J AM STAT ASSOC, V84, P549