Tunable plasmonic glucose sensing based on the dissociation of Con A-aggregated dextran-coated gold colloids

被引:45
作者
Aslan, K
Lakowicz, JR
Geddes, CD
机构
[1] Univ Maryland, Inst Biotechnol, Ctr Med Biotechnol, Inst Fluorescence, Baltimore, MD 21201 USA
[2] Univ Maryland, Sch Med, Dept Biochem, Ctr Fluorescence Spect, Baltimore, MD 21201 USA
[3] Univ Maryland, Sch Med, Ctr Med Biotechnol, Ctr Fluorescence Spect,Dept Biochem & Mol Biol, Baltimore, MD 21201 USA
关键词
gold colloids; tunable glucose sensor(s); plasmonic nanosensors;
D O I
10.1016/j.aca.2004.04.060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe a new approach for glucose determination with tunable glucose dynamic sensing ranges, dependent on the properties of new nanosensors, which are comprised of Con A-aggregated dextran-coated gold colloids. Dextran-coated 10 or 20 nm gold colloids can be aggregated with Con A in a controlled fashion, the change in absorbance at an arbitrary wavelength used to monitor the extent of aggregation, which can be optimized for sensing. The presence of any glucose competitively binds with Con A, dissociating the dextran-coated colloids, affording for the reverse gold plasmon change and hence the determination of glucose concentrations. For one of our sensor systems, a 500K dextran-20 nm gold sensor, crosslinked with 8.70 muM Con A, a change in absorbance at 650 nm of 0.03 was observed, in response to as little as 3 mM glucose. In contrast, a 500K dextran-10 nm gold 18.7 muM Con A aggregate sensor, produced a 0.05 and 0.1 change in absorbance, respectively, by the addition of 50 and 100 mM glucose. We have found that the glucose sensing ranges can be somewhat tuned by altering the properties, and therefore the extent of aggregation of the gold aggregate sensors. Reducing the gold colloid size and dextran molecular weight typically reduces the glucose sensing range (lower [glucose]) but also reduces the long-term stability of the gold aggregate sensor. Similarly the concentration of Con A used to aggregate the system also has an effect on long term sensor stability and glucose response. In this paper, we present our findings, which offer unique opportunities and perspectives for building tunable plasmonic type glucose sensors. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 32 条
[1]   Surface modification of colloidal gold by chemisorption of alkanethiols in the presence of a nonionic surfactant [J].
Aslan, K ;
Pérez-Luna, VH .
LANGMUIR, 2002, 18 (16) :6059-6065
[2]   Noninvasive continuous monitoring of physiological glucose using a monosaccharide-sensing contact lens [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :610-618
[3]   A glucose sensing contact lens: A non-invasive technique for continuous physiological glucose monitoring [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
JOURNAL OF FLUORESCENCE, 2003, 13 (05) :371-374
[4]  
BADUGU R, 2004, BIOPHOTONICS INT, V11, P50
[5]   A fluorescence affinity hollow fiber sensor for continuous transdermal glucose monitoring [J].
Ballerstadt, R ;
Schultz, JS .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4185-4192
[6]   Metal nanocolloids [J].
Belloni, J .
CURRENT OPINION IN COLLOID & INTERFACE SCIENCE, 1996, 1 (02) :184-196
[7]   Influencing receptor-ligand binding mechanisms with multivalent ligand architecture [J].
Gestwicki, JE ;
Cairo, CW ;
Strong, LE ;
Oetjen, KA ;
Kiessling, LL .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (50) :14922-14933
[8]   NONINVASIVE BLOOD-GLUCOSE SENSORS BASED ON NEAR-INFRARED SPECTROSCOPY [J].
HEISE, HM ;
MARBACH, R ;
KOSCHINSKY, T ;
GRIES, FA .
ARTIFICIAL ORGANS, 1994, 18 (06) :439-447
[9]   PHYSICOCHEMICAL PROPERTIES OF SMALL METAL PARTICLES IN SOLUTION - MICROELECTRODE REACTIONS, CHEMISORPTION, COMPOSITE METAL PARTICLES, AND THE ATOM-TO-METAL TRANSITION [J].
HENGLEIN, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1993, 97 (21) :5457-5471
[10]   Gold nanoparticle-based sensing of "spectroscopically silent" heavy metal ions [J].
Kim, YJ ;
Johnson, RC ;
Hupp, JT .
NANO LETTERS, 2001, 1 (04) :165-167