Automated on-line ionic detergent removal from minute protein/peptide samples prior to liquid chromatography electrospray mass spectrometry

被引:23
作者
Vissers, JPC [1 ]
Hulst, WP [1 ]
Chervet, JP [1 ]
Snijders, HMJ [1 ]
Cramers, CA [1 ]
机构
[1] EINDHOVEN UNIV TECHNOL,INSTRUMENTAL ANAL LAB,NL-5600 MB EINDHOVEN,NETHERLANDS
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1996年 / 686卷 / 02期
关键词
detergents; ionic detergent removal; proteins; peptides;
D O I
10.1016/S0378-4347(96)00213-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automated on-line ionic detergent removal pre-column system coupled to capillary liquid chromatography-electrospray mass spectrometry is described. The system involves two micro precolumns, composed of a specific ionic detergent trapping column and a preconcentration column, respectively, and a packed 300 mu m I.D. analytical column. Sample loading to the micro precolumns and regeneration of the detergent trapping column were performed at a flow-rate of 50 mu l/min, while the flow-rate through the analytical column was set at 5.0 mu l/min. Ionic detergent-containing tryptic-digested protein samples were directly applied to the micro precolumns without sample pretreatment and were analysed by UV absorption detection and electrospray mass spectrometry. The presented system allows for the fully automated removal of SDS with virtually no loss in protein/peptides. Maximum SDS load and breakthrough have been determined. Excellent protein recovery and complete removal of SDS is found. The chromatographic separation after SDS removal was completely restored and equalled the reference chromatogram Mass spectral data confirm these findings. Finally, this technique allows for SDS removal from minute protein samples without the need for any sample handling.
引用
收藏
页码:119 / 128
页数:10
相关论文
共 14 条
[1]   REMOVAL OF SODIUM DODECYL-SULFATE FROM PROTEINS AND PEPTIDES BY GEL-FILTRATION [J].
AMONS, R ;
SCHRIER, PI .
ANALYTICAL BIOCHEMISTRY, 1981, 116 (02) :439-443
[2]   MICROPREPARATIVE SEPARATION OF PEPTIDES DERIVED FROM SODIUM DODECYL SULFATE-SOLUBILIZED PROTEINS [J].
BOSSERHOFF, A ;
WALLACH, J ;
FRANK, RW .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (01) :71-77
[3]  
BURKHART W, 1993, TECHNIQUES PROTEIN C, V4, P399
[4]  
CHERVET JP, 1989, HRC-J HIGH RES CHROM, V12, P278
[5]   Z-SHAPED FLOW CELL FOR UV-DETECTION IN CAPILLARY ELECTROPHORESIS [J].
CHERVET, JP ;
VANSOEST, REJ ;
URSEM, M .
JOURNAL OF CHROMATOGRAPHY, 1991, 543 (02) :439-449
[6]  
CHERVET JP, 1992, LC GC-MAG SEP SCI, V10, P140
[7]   REMOVAL OF SODIUM DODECYL-SULFATE FROM PROTEINS ISOLATED BY SODIUM DODECYL-SULFATE POLYACRYLAMIDE-GEL ELECTROPHORESIS [J].
KAPLAN, B ;
PRAS, M .
BIOMEDICAL CHROMATOGRAPHY, 1990, 4 (02) :89-90
[8]   REMOVAL OF SODIUM DODECYL-SULFATE FROM PROTEINS BY GEL-PERMEATION CHROMATOGRAPHY [J].
KAPLAN, B ;
PRAS, M .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 423 :376-379
[9]  
KONIGSBERG WH, 1983, METHOD ENZYMOL, V91, P254
[10]   CHARACTERIZATION OF HUMANIZED ANTI-TAC, AN ANTIBODY-DIRECTED AGAINST THE INTERLEUKIN-2 RECEPTOR, USING ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY BY DIRECT INFUSION, LC/MS, AND MS/MS [J].
LEWIS, DA ;
GUZZETTA, AW ;
HANCOCK, WS ;
COSTELLO, M .
ANALYTICAL CHEMISTRY, 1994, 66 (05) :585-595