An amperometric Meldola Blue-mediated sensor high sensitive to hydrogen peroxide based on immobilization of horseradish peroxidase in a composite membrane of regenerated silk fibroin and poly(vinyl alcohol)

被引:22
作者
Liu, HY
Zhang, XL
Wei, JJ
Wu, XX
Qi, DY
Liu, YC
Dai, M
Yu, TY
Deng, JQ
机构
[1] FUDAN UNIV,DEPT MACROMOLEC SCI,SHANGHAI 200433,PEOPLES R CHINA
[2] FUDAN UNIV,DEPT CHEM,SHANGHAI 200433,PEOPLES R CHINA
基金
上海市自然科学基金; 中国国家自然科学基金;
关键词
sensors; poly(vinyl alcohol); regenerated silk fibroin; Meldola Blue; horseradish peroxidase; hydrogen peroxide;
D O I
10.1016/0003-2670(96)00130-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new composite membrane of poly(vinyl alcohol) (PVA) and regenerated silk fibroin (RSF) was successfully employed to immobilize horseradish peroxidase (HRP) and infrared (IR) was used to get insight in the structure of the composite membrane. An amperometric HRP-based sensor highly sensitive to hydrogen peroxide was fabricated, which was based on Meldola Blue as a mediator to facilitate efficient electron transfer between immobilized HRP and a glassy carbon electrode. Performance and characteristics of the sensor were evaluated with respect to response time, detection limit, selectivity, operating and storage stability, and dependence on temperature, pH, applied potential and mediator concentration. The sensor displayed high sensitivity to hydrogen peroxide with low detection of limit of 0.1 mu M.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 25 条
[1]   TTF-MODIFIED BIOSENSORS FOR HYDROGEN-PEROXIDE [J].
BIFULCO, L ;
CAMMAROTO, C ;
NEWMAN, JD ;
TURNER, APF .
ANALYTICAL LETTERS, 1994, 27 (08) :1443-1452
[2]   A METHOD FOR ESTIMATION OF HYDROGEN-PEROXIDE BASED ON MEDIATED ELECTRON-TRANSFER REACTIONS OF PEROXIDASES AT ELECTRODES [J].
FREW, JE ;
HARMER, MA ;
HILL, HAO ;
LIBOR, SI .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 201 (01) :1-10
[3]   AMPEROMETRIC SENSORS FOR PEROXIDE, CHOLINE, AND ACETYLCHOLINE BASED ON ELECTRON-TRANSFER BETWEEN HORSERADISH-PEROXIDASE AND A REDOX POLYMER [J].
GARGUILO, MG ;
HUYNH, N ;
PROCTOR, A ;
MICHAEL, AC .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :523-528
[4]   MEDIATORLESS HORSERADISH-PEROXIDASE ENZYME ELECTRODES BASED ON ACTIVATED CARBON - POTENTIAL APPLICATION TO SPECIFIC BINDING ASSAY [J].
HO, WO ;
ATHEY, D ;
MCNEIL, CJ ;
HAGER, HJ ;
EVANS, GP ;
MULLEN, WH .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 351 (1-2) :185-197
[5]   ACCURACY OF DETERMINATION OF HYDROGEN PEROXIDE BY CERATE OXIDIMETRY [J].
HURDIS, EC ;
ROMEYN, H .
ANALYTICAL CHEMISTRY, 1954, 26 (02) :320-325
[6]   AN ELECTROCHEMICAL SENSOR FOR HYDROGEN-PEROXIDE BASED ON PEROXIDASE ADSORBED ON A SPECTROGRAPHIC GRAPHITE ELECTRODE [J].
JONSSON, G ;
GORTON, L .
ELECTROANALYSIS, 1989, 1 (05) :465-468
[7]   ROTATING-RING-DISK ENZYME ELECTRODE FOR BIOCATALYSIS KINETIC-STUDIES AND CHARACTERIZATION OF THE IMMOBILIZED ENZYME LAYER [J].
KAMIN, RA ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1980, 52 (08) :1198-1205
[8]   NOVEL MEMBRANELESS AMPEROMETRIC PEROXIDE BIOSENSOR BASED ON A TETRATHIAFULVALENE-P-TETRACYANOQUINODIMETHANE ELECTRODE [J].
KORELL, U ;
SPICHIGER, UE .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :510-515
[9]   ELECTRON EXCHANGE BETWEEN THE ENZYME ACTIVE-CENTER AND ORGANIC METAL [J].
KULYS, JJ ;
SAMALIUS, AS ;
SVIRMICKAS, GJS .
FEBS LETTERS, 1980, 114 (01) :7-10
[10]   NICKELOCENE-MEDIATING SENSOR FOR HYDROGEN-PEROXIDE BASED ON BIOELECTROCATALYTIC REDUCTION OF HYDROGEN-PEROXIDE [J].
LIU, HY ;
QIAN, JH ;
LIU, YC ;
YU, TY ;
DENG, JQ .
ANALYTICAL PROCEEDINGS, 1995, 32 (11) :475-477