Fundamental aspects of electrospray droplet impact/SIMS

被引:75
作者
Hiraoka, Kenzo [1 ]
Mori, Kunihiko [1 ]
Asakawa, Daiki [1 ]
机构
[1] Univ Yamanashi, Clean Energy Res Ctr, Kofu, Yamanashi 4008510, Japan
来源
JOURNAL OF MASS SPECTROMETRY | 2006年 / 41卷 / 07期
关键词
electrospray droplet impact; SIMS; massive cluster impact;
D O I
10.1002/jms.1048
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new ionization method, electrospray droplet impact ionization (EDI), has been developed for matrix-free secondary-ion mass spectrometry (SIMS). The charged droplets formed by electrospraying 1 M acetic acid aqueous solution are sampled through an orifice with a diameter of 400 mu m into the first vacuum chamber, transported into a quadrupole ion guide, and accelerated by 10 kV after exiting the ion guide. The droplets impact on a dry solid sample (no matrix used) deposited on a stainless steel substrate. The secondary ions formed by the impact are transported to a second quadrupole ion guide and mass-analyzed by an orthogonal time-of-flight mass spectrometer (TOF-MS). Ten pmol of gramicidin S could be detected with the presence of as much as 10 nmol of NaCl. The ion signal for arginine disappeared with decrease in the substrate temperature below 150 K owing to the formation of ice film over the sample surface. While 10 fmol of gramicidin S could be detected for 30 min, the ionization/desorption efficiency for EDI becomes smaller with an increase in the molecular weight (MW) of a biological sample. The largest protein samples detected to date are cytochrome c and lysozyme. The high sensitivity for EDI is due to the fact that samples only a few monolayers thick are subject to desorption/ionization by EDI, with little fragmentation. A coherent phonon excitation may be the main mechanism for the desorption/ionization of the solid sample. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:894 / 902
页数:9
相关论文
共 26 条
[1]   SECONDARY ION MASS-SPECTROMETRY WITH CESIUM ION PRIMARY BEAM AND LIQUID TARGET MATRIX FOR ANALYSIS OF BIOORGANIC COMPOUNDS [J].
ABERTH, W ;
STRAUB, KM ;
BURLINGAME, AL .
ANALYTICAL CHEMISTRY, 1982, 54 (12) :2029-2034
[2]   Impact desolvation of electrosprayed microdroplets - a new ionization method for mass spectrometry of large biomolecules [J].
Aksyonov, SA ;
Williams, P .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (21) :2001-2006
[3]   COMPARISON OF POLYATOMIC AND ATOMIC PRIMARY BEAMS FOR SECONDARY ION MASS-SPECTROMETRY OF ORGANICS [J].
APPELHANS, AD ;
DELMORE, JE .
ANALYTICAL CHEMISTRY, 1989, 61 (10) :1087-1093
[4]  
ASAKAWA D, IN PRESS
[5]   FAST ATOM BOMBARDMENT OF SOLIDS (FAB) - A NEW ION-SOURCE FOR MASS-SPECTROMETRY [J].
BARBER, M ;
BORDOLI, RS ;
SEDGWICK, RD ;
TYLER, AN .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1981, (07) :325-327
[6]   MASS DISTRIBUTIONS OF IONS SPUTTERED BY CLUSTER IMPACTS ON CARBON, COPPER AND GOLD TARGETS [J].
BEUHLER, RJ ;
FRIEDMAN, L .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 94 (1-2) :25-39
[7]   SECONDARY-ION YIELDS FROM SURFACES BOMBARDED WITH KEV MOLECULAR AND CLUSTER IONS [J].
BLAIN, MG ;
DELLANEGRA, S ;
JORET, H ;
LEBEYEC, Y ;
SCHWEIKERT, EA .
PHYSICAL REVIEW LETTERS, 1989, 63 (15) :1625-1628
[8]   SURFACE SECONDARY-ELECTRON AND SECONDARY-ION EMISSION INDUCED BY LARGE MOLECULAR ION IMPACTS [J].
BRUNELLE, A ;
CHAURAND, P ;
DELLANEGRA, S ;
LEBEYEC, Y ;
BAPTISTA, GB .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 126 :65-73
[9]   EFFECT OF CLUSTER SURFACE ENERGIES ON SECONDARY-ION-INTENSITY DISTRIBUTIONS FROM IONIC-CRYSTALS [J].
CAMPANA, JE ;
BARLAK, TM ;
COLTON, RJ ;
DECORPO, JJ ;
WYATT, JR ;
DUNLAP, BI .
PHYSICAL REVIEW LETTERS, 1981, 47 (15) :1046-1049
[10]  
CORNETT DS, 1994, RAPID COMMUN MASS SP, V8, P996