Fluoroscopic views for safe insertion of lag screws into the posterior column of the acetabulum

被引:21
作者
Chen, Wei [1 ]
Zhang, Zekun [2 ]
Lu, Yang [1 ]
Li, Jia [1 ]
Zhang, Yingze [1 ]
Shen, Yong [1 ]
机构
[1] Hebei Med Univ, Dept Orthopaed Surg, Hosp 3, Shijiazhuang 050051, Hebei, Peoples R China
[2] Hebei Med Univ, Dept Radiol, Hosp 3, Shijiazhuang 050051, Hebei, Peoples R China
基金
中国国家自然科学基金;
关键词
Acetabular fracture; Posterior column; Percutaneous fixation; Fluoroscopic view; MULTIPLANAR COMPUTED-TOMOGRAPHY; INTRAOPERATIVE FLUOROSCOPY; FRACTURE REDUCTION; INTERNAL-FIXATION; SURGERY; NAVIGATION; PLACEMENT; ACCURACY;
D O I
10.1186/1471-2474-15-303
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: Percutaneous lag screw fixation is an alternative treatment for non-displaced or minimally displaced posterior column fractures. This study aims to explore new fluoroscopic views of the acetabulum for safe percutaneous insertion of posterior column lag screws. Methods: Axial computed tomography (CT) scans were taken of sixteen embalmed adult cadavers. The axial CT images at the level of the middle height of the acetabulum were selected. The angle (angle alpha) between the posterior cortex of the posterior column (PCPC) and the line intersecting the axial plane and the coronal plane, and the angle (angle beta) between the medial wall and the line intersecting the axial plane and the sagittal plane were identified and measured. Tangential views of the PCPC and medial wall were obtained by referencing the measured angles. A lag screw was inserted into the posterior columns of the sixteen pelvic specimens under fluoroscopic guidance using an iliac oblique view and the two tangential views. CT scans were performed to evaluate the lag screw position. Axial CT images of 52 volunteers were obtained and the angles alpha and beta were measured following the same methods used for the cadaveric specimens. Results: The angles alpha and beta for the specimens were 29.3 +/- 2.8.1 and 8.1 +/- 1.4 degrees, respectively. On the tangential view of the PCPC, the posterior cortex appears as a nearly straight line between the lesser and greater sciatic notches. On the tangential view of the medial wall, the medial wall appears as a distinct straight line. Using these radiographic images, the lag screws were inserted into the posterior columns of bony pelvic specimens. Screw placement was confirmed by CT, and found to be fully intraosseous in all cases without any cortical breaches. The angles alpha and beta were 30.4 +/- 4.1 and 9.2 +/- 1.9 degrees for male volunteers and 28.5 +/- 3.7 and 7.7 +/- 1.8 degrees for female volunteers, significant difference in these angles between cadaveric specimens and human volunteers. Conclusion: The tangential views of both the PCPC and medial wall can be obtained following the aforementioned methods The oblique iliac view and the two tangential views enable safe insertion of posterior column lag screws.
引用
收藏
页数:7
相关论文
共 31 条
[1]
Brown GA, 2000, CLIN ORTHOP RELAT R, P219
[2]
Accuracy of detecting screw penetration of the acetabulum with intraoperative fluoroscopy and computed tomography [J].
Carmack, DB ;
Moed, BR ;
McCarroll, K ;
Freccero, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (09) :1370-1375
[3]
Ebraheim N A, 1989, J Orthop Trauma, V3, P196, DOI 10.1097/00005131-198909000-00003
[4]
PERCUTANEOUS SCREW FIXATION OF ACETABULAR FRACTURES WITH CT GUIDANCE - PRELIMINARY-RESULTS OF A NEW TECHNIQUE [J].
GAY, SB ;
SISTROM, C ;
WANG, GJ ;
KAHLER, DA ;
BOMAN, T ;
MCHUGH, N ;
GOITZ, HT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (04) :819-822
[5]
Imaging of the acetabulum in the era of multidetector computed tomography [J].
Geijer M. ;
El-Khoury G.Y. .
Emergency Radiology, 2007, 14 (5) :271-287
[6]
2D-fluoroscopic navigated screw osteosynthesis of acetabular fractures:: A preliminary report [J].
Gras, F. ;
Marintschev, I. ;
Mendler, F. ;
Wilharm, A. ;
Mueckley, T. ;
Hofmann, G. O. .
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2008, 146 (02) :231-239
[7]
Screw Placement for Acetabular Fractures: Which Navigation Modality (2-Dimensional vs. 3-Dimensional) Should Be Used? An Experimental Study [J].
Gras, Florian ;
Marintschev, Ivan ;
Klos, Kajetan ;
Mueckley, Thomas ;
Hofmann, Gunther O. ;
Kahler, David M. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (08) :466-473
[8]
Helfet DL, 1998, MASTER TECHNIQUES OR, P675
[9]
Navigated Long-Bone Fracture Reduction [J].
Kahler, David M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A :102-107
[10]
Kellam JP, 1995, FRACTURES PELVIS ACE, P355