Laboratory tests of pulse shape discrimination techniques for correcting the effects of radiation damage in germanium coaxial detectors

被引:5
作者
Boggs, SE
Hull, EL
Lin, RP
Madden, NW
McBride, S
Pehl, RH
Primbsch, JH
Slassi-Sennou, S
机构
[1] CALTECH, Space Radiat Lab, Pasadena, CA 91125 USA
[2] Univ Calif Berkeley, Space Sci Lab, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Lawrence Berkeley Lab, Berkeley, CA 94720 USA
[4] Indiana Univ, Cyclotron Facil, Bloomington, IN 47408 USA
基金
美国国家航空航天局;
关键词
germanium; detectors; gamma-ray; radiation damage;
D O I
10.1016/S0168-9002(99)01047-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A reverse-electrode closed-end germanium coaxial detector was irradiated with 183-MeV neutrons to evaluate the value of Pulse Shape Discrimination (PSD) techniques in restoring the energy resolution and line shape of the radiation damaged detector. Two consecutive irradiations were performed for total fluences of 5.0 x 10(8) and 10.4 x 10(8) n/cm(2), with PSD tests performed after each irradiation. These irradiations degraded the energy resolution and line shapes; however, PSD corrections significantly restored the performance, even after severe damage. These PSD techniques delay and potentially eliminate, in some experimental situations, the need to anneal germanium detectors in damaging radiation environments, (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 8 条
[1]   Pulse-shape discrimination techniques for correcting the effects of radiation damage in germanium coaxial detectors [J].
Ho, WCG ;
Boggs, SE ;
Lin, RP ;
Slassi-Sennou, S ;
Madden, NW ;
Pehl, RH ;
Hull, EL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 412 (2-3) :507-514
[2]   EFFECTS PRODUCED BY FAST NEUTRON BOMBARDMENT OF GE(LI) GAMMA RAY DETECTORS [J].
KRANER, HW ;
CHASMAN, C ;
JONES, KW .
NUCLEAR INSTRUMENTS & METHODS, 1968, 62 (02) :173-+
[3]   The spectrometer SPI of the INTEGRAL mission [J].
Lichti, GG ;
Schonfelder, V ;
Diehl, R ;
Georgii, R ;
Kirchner, T ;
Vedrenne, G ;
Mandrou, P ;
vonBallmoos, P ;
Jean, P ;
Albernhe, F ;
Durouchoux, P ;
Cordier, B ;
Diallo, N ;
Sanchez, F ;
Leleux, P ;
Caraveo, PA ;
Teegarden, B ;
Matteson, J ;
Lin, R ;
Skinner, GK ;
Connell, P .
GAMMA-RAY AND COSMIC-RAY DETECTORS, TECHNIQUES, AND MISSIONS, 1996, 2806 :217-233
[4]  
MATTESON J, 1990, 21ST P INT COSM RAY, V2, P174
[5]   HIGH-ENERGY PROTON RADIATION-DAMAGE OF HIGH-PURITY GERMANIUM DETECTORS [J].
PEHL, RH ;
VARNELL, LS ;
METZGER, AE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) :409-417
[6]   Simulations of pulse shape discrimination (PSD) techniques for background reduction in germanium detectors [J].
Philhour, B ;
Boggs, SE ;
Primbsch, JH ;
Slassi-Sennou, AS ;
Lin, RP ;
Feffer, PT ;
McBride, S ;
Goulding, FS ;
Madden, NW ;
Pehl, RH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 403 (01) :136-150
[7]   Laboratory tests and simulations of pulse shape discrimination (PSD) technique for background reduction in germanium gamma ray detectors [J].
SlassiSennou, SA ;
Boggs, SE ;
Philhour, B ;
Campbell, R ;
Feffer, PT ;
Lin, RP ;
McBride, S ;
Primbsch, HJ ;
Cork, CP ;
Goulding, FS ;
Luke, PN ;
Madden, NW ;
Malone, DF ;
Pehl, RH .
GAMMA-RAY AND COSMIC-RAY DETECTORS, TECHNIQUES, AND MISSIONS, 1996, 2806 :483-492
[8]  
VIGDOR SE, 1992, PHYS REV C, V46, P460