Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities

被引:126
作者
Belmont, PJ
Klemme, WR
Robinson, M
Polly, DW
机构
[1] Walter Reed Army Med Ctr, Dept Orthopaed Surg, Washington, DC 20307 USA
[2] Uniformed Serv Univ Hlth Sci, Dept Surg, Bethesda, MD 20814 USA
关键词
pedicle screw; thoracic spine; accuracy; computed tomography; scoliosis; transverse screw angle; spinal fixation;
D O I
10.1097/00007632-200207150-00015
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. This retrospective observational study evaluated 399 transpedicular thoracic screws using postoperative computed tomography (CT). Objectives. To examine the in vivo accuracy of transpedicular thoracic screws in patients with and without coronal plane spinal deformities. Summary of Background Data, There are no comparative studies regarding the safety and accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities. Methods. Curve magnitude and segmental vertebral rotation were determined from preoperative radiographs. Postoperative CT was used to assess the placement accuracy of titanium thoracic pedicle screws. Results. Forty-seven patients underwent instrumented posterior spinal fusion using 399 titanium thoracic pedicle screws. Fully contained screw accuracy in patients with coronal plane spinal deformities was less than in patients without coronal plane spinal deformities at T9-T12 (59% vs. 73%, P = 0.04) and overall (42% vs. 62%, P = 0.001). There was no difference between the overall percentages of acceptably positioned screws (less than or equal to2 mm of medial or less than or equal to 6 mm of lateral pedicle perforation) in patients with coronal plane spinal deformities (98 to) versus patients without coronal plane spinal deformities (99%) (P = 0.69). Penetration of the anterior vertebral cortex was more frequent in patients with coronal plane spinal deformities than in those without coronal plane spinal deformities (8.0% vs. 1.0% , P = 0.008). There was no correlation between the accuracy of screw placement and the degree of segmental rotation, screw proximity to the curve apex, or screw position relative to the curve concavity or convexity (P > 0.12). There were no neurologic or vascular complications. Conclusions. The overall percentage of acceptably positioned screws was 98% in patients with corona] plane spinal deformities and 99% in patients without corona] plane spinal deformities. In patients with coronal plane spinal deformities, penetration of the pedicle wall and the anterior vertebral cortex was increased at T9-T12 and overall.
引用
收藏
页码:1558 / 1566
页数:9
相关论文
共 42 条
  • [1] Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    Amiot, LP
    Lang, K
    Putzier, M
    Zippel, H
    Labelle, H
    [J]. SPINE, 2000, 25 (05) : 606 - 614
  • [2] In vivo accuracy of thoracic pedicle screws
    Belmont, PJ
    Klemme, WR
    Dhawan, A
    Polly, DW
    [J]. SPINE, 2001, 26 (21) : 2340 - 2346
  • [3] Reliability of pedicle screw assessment utilizing plain radiographs versus CT reconstruction
    Berlemann U.
    Heini P.
    Müller U.
    Stoupis C.
    Schwarzenbach O.
    [J]. European Spine Journal, 1997, 6 (6) : 406 - 410
  • [4] Berlet GC, 1999, J SPINAL DISORD, V12, P234
  • [5] A MORPHOMETRIC STUDY OF HUMAN LUMBAR AND SELECTED THORACIC VERTEBRAE
    BERRY, JL
    MORAN, JM
    BERG, WS
    STEFFEE, AD
    [J]. SPINE, 1987, 12 (04) : 362 - 367
  • [6] Complications of pediatric thoracolumbar and lumbar pedicle screws
    Brown, CA
    Lenke, LG
    Bridwell, KH
    Geideman, WM
    Hasan, SA
    Blanke, K
    [J]. SPINE, 1998, 23 (14) : 1566 - 1571
  • [7] Accuracy of pedicle screw placement in lumbar vertebrae
    Castro, WHM
    Halm, H
    Jerosch, J
    Malms, J
    Steinbeck, J
    Blasius, S
    [J]. SPINE, 1996, 21 (11) : 1320 - 1324
  • [8] Pedicle instrumentation in the thoracic spine - A morphometric and cadaveric study for placement of screws
    Cinotti, G
    Gumina, S
    Ripani, M
    Postacchini, F
    [J]. SPINE, 1999, 24 (02) : 114 - 119
  • [9] A three-dimensional radiographic comparison of Cotrel-Dubousset and Colorado instrumentations for the correction of idiopathic scoliosis
    Delorme, S
    Labelle, H
    Aubin, CÉ
    de Guise, JA
    Rivard, CH
    Poitras, B
    Dansereau, J
    [J]. SPINE, 2000, 25 (02) : 205 - 210
  • [10] AN ANATOMIC, RADIOGRAPHIC, AND BIOMECHANICAL ASSESSMENT OF EXTRAPEDICULAR SCREW FIXATION IN THE THORACIC SPINE
    DVORAK, M
    MACDONALD, S
    GURR, KR
    BAILEY, SI
    HADDAD, RG
    [J]. SPINE, 1993, 18 (12) : 1689 - 1694