Relative cerebral blood volume measurements in intracranial mass lesions: Interobserver and intraobserver reproducibility study

被引:198
作者
Wetzel, SG
Cha, SM
Johnson, G
Lee, P
Law, M
Kasow, DL
Pierce, SD
Xue, XN
机构
[1] NYU, Sch Med, Dept Radiol, New York, NY 10016 USA
[2] NYU, Sch Med, Dept Environm Med, Div Biostat, New York, NY 10016 USA
关键词
brain; blood flow; brain neoplasms; MR;
D O I
10.1148/radiol.2243011014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess inter- and intraobserver reproducibility for different techniques of measuring relative cerebral blood volume (rCBV) in patients with intracranial mass lesions. MATERIALS AND METHODS: Three independent observers (neuroradiology fellows) who were blinded to the histopathologic diagnosis performed rCBV measurements in 50 patients with various intracranial mass lesions. Three different methods were compared. With method 1, placement of a single region of interest was guided by a color overlay map. With methods 2 and 3, the highest rCBV value and the mean of repeated rCBV measurements, respectively, were recorded. Calculations of the intraclass correlation coefficient, coefficient of variation (CV), and descriptive statistics were used to determine the levels of reproducibility. A multiple linear regression model was used to evaluate for possible explanatory factors for interobserver variance. RESULTS: Method 2 had, overall, the best reproducibility of all techniques, with an intraclass interobserver correlation coefficient of 0.71 (indicating good agreement), interobserver CV of 30%, and intraobserver CV in the range of 32%-41%. Measurement variations between observers correlated significantly (P < .001) with increasing rCBV values. CONCLUSION: In this study, interobserver and intraobserver reproducibility of rCBV measurements were clinically acceptable. (C) RSNA, 2002.
引用
收藏
页码:797 / 803
页数:7
相关论文
共 19 条
[1]   CEREBRAL BLOOD-VOLUME MAPS OF GLIOMAS - COMPARISON WITH TUMOR GRADE AND HISTOLOGIC-FINDINGS [J].
ARONEN, HJ ;
GAZIT, IE ;
LOUIS, DN ;
BUCHBINDER, BR ;
PARDO, FS ;
WEISSKOFF, RM ;
HARSH, GR ;
COSGROVE, GR ;
HALPERN, EF ;
HOCHBERG, FH ;
ROSEN, BR .
RADIOLOGY, 1994, 191 (01) :41-51
[2]   METHODS AND THEORY OF RELIABILITY [J].
BARTKO, JJ ;
CARPENTER, WT .
JOURNAL OF NERVOUS AND MENTAL DISEASE, 1976, 163 (05) :307-317
[3]  
Cha S, 2000, AM J NEURORADIOL, V21, P881
[4]  
Dachman AH, 2001, CANCER, V91, P555, DOI 10.1002/1097-0142(20010201)91:3<555::AID-CNCR1034>3.0.CO
[5]  
2-F
[6]   GLIOMAS - CLASSIFICATION WITH MR IMAGING [J].
DEAN, BL ;
DRAYER, BP ;
BIRD, CR ;
FLOM, RA ;
HODAK, JA ;
COONS, SW ;
CAREY, RG .
RADIOLOGY, 1990, 174 (02) :411-415
[7]   Comparison of cerebral blood volume measurements using the T1 and T2* methods in normal human brains and brain tumors [J].
Hacklander, T ;
Reichenbach, JR ;
Modder, U .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (06) :857-866
[8]  
Haselhorst R, 2000, JMRI-J MAGN RESON IM, V11, P495, DOI 10.1002/(SICI)1522-2586(200005)11:5<495::AID-JMRI5>3.0.CO
[9]  
2-S
[10]  
JOHNSON G, 2001, P 9 M INT SOC MAGN R, P1588