Quantitative colorectal cancer perfusion measurement by multidetector-row CT: does greater tumour coverage improve measurement reproducibility?

被引:26
作者
Goh, V.
Halligan, S.
Gartner, L.
Bassett, P.
Bartram, C. I.
机构
[1] St Marks Hosp, Intestinal Imaging Ctr, Harrow HA1 3UJ, Middx, England
[2] Mt Vernon Hosp, Paul Strickland Scanner Ctr, Northwood HA6 2RN, Middx, England
关键词
D O I
10.1259/bjr/18842556
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The purpose of this study was to determine if greater z-axis tumour coverage improves the reproducibility of quantitative colorectal cancer perfusion measurements using CT. A 65 s perfusion study was acquired following intravenous contrast administration in 10 patients with proven colorectal cancer using a four-detector row scanner. This was repeated within 48 h using identical technical parameters to allow reproducibility assessment. Quantitative tumour blood volume, blood flow, mean transit time and permeability measurements were determined using commercially available software (Perfusion 3.0; GE Healthcare, Waukesha, WI) for data obtained from a 5 mm z-axis tumour coverage, and from a 20 mm z-axis tumour coverage. Measurement reproducibility was assessed using Bland-Altman statistics, for a 5 mm z-axis tumour coverage, and 20 mm z-axis tumour coverage, respectively. The mean difference (95% limits of agreement) for blood volume, blood flow, mean transit time and permeability were 0.04 (-2.50 to +2.43) ml/100 g tissue; +8.80 (-50.5 to +68.0) ml/100 g tissue/min; -0.99 (-8.19 to +6.20) seconds; and +1.20 (-5.42 to +7.83) ml/100 g tissue/min, respectively, for a 5 mm coverage, and -0.04 (-2.61 to +2.53) ml/100 g tissue; +7.40 (-50.3 to +65.0) ml/100 g tissue/min; -2.46 (-12.61 to +7.69) seconds; and -0.23 (-8.31 to +7.85) ml/100 g tissue/min, respectively, for a 20 mm coverage, indicating similar levels of agreement. In conclusion, increasing z-axis coverage does not improve reproducibility of quantitative colorectal cancer perfusion measurements.
引用
收藏
页码:578 / 583
页数:6
相关论文
共 20 条
[1]
Applying the right statistics: analyses of measurement studies [J].
Bland, JM ;
Altman, DG .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) :85-93
[2]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]
Bland M., 2003, An introduction to medical statistics, V3rd
[4]
Cenic A, 2000, AM J NEURORADIOL, V21, P462
[5]
Endrich B, 2000, MED RAD DIA IMG, P19
[6]
Reproducibility of dynamic contrast-enhanced MRI in human muscle and tumours: comparison of quantitative and semi-quantitative analysis [J].
Galbraith, SM ;
Lodge, MA ;
Taylor, NJ ;
Rustin, GJS ;
Bentzen, S ;
Stirling, JJ ;
Padhani, AR .
NMR IN BIOMEDICINE, 2002, 15 (02) :132-142
[7]
Combretastatin A4 phosphate has tumor antivascular activity in rat and man as demonstrated by dynamic magnetic resonance imaging [J].
Galbraith, SM ;
Maxwell, RJ ;
Lodge, MA ;
Tozer, GM ;
Wilson, J ;
Taylor, NJ ;
Stirling, JJ ;
Sena, L ;
Padhani, AR ;
Rustin, GJS .
JOURNAL OF CLINICAL ONCOLOGY, 2003, 21 (15) :2831-2842
[8]
Reproducibility of quantitative CT perfusion imaging [J].
Gillard, JH ;
Antoun, NM ;
Burnet, NG ;
Pickard, JD .
BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (882) :552-555
[9]
Quantitative assessment of colorectal cancer perfusion using MDCT: inter- and intraobserver agreement [J].
Goh, V ;
Halligan, S ;
Hugill, JA ;
Bassett, P ;
Bartram, CI .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (01) :225-231
[10]
GOH V, 2004, RAD SOC N AM 90 SCI