Volumetric ultrasound system for left ventricle motion imaging

被引:17
作者
Canals, R
Lamarque, G
Chatain, P
机构
[1] Univ Orleans, Lab Elect Signals Images, F-45067 Orleans, France
[2] Vermon, F-37000 Tours, France
关键词
D O I
10.1109/58.808877
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
An external ultrasound oscillating probe has been developed for the purpose of visualizing dynamically the left cardiac ventricle three-dimensional (3D) movements and deformations. The fundamental principle of this probe is to maintain in continuous oscillation a classical one-dimensional (1D) transducer array around its axis at a maximum oscillation rate of 3 degrees per millisecond. A global medical system, including hardware elements and a software package, has been designed for this application. A motorization set and electronic boards enable this new oscillating probe to be used with any recent echograph equipped with a cardiac module and an external triggering cineloop. Moreover, in order to obtain 3D/4D left ventricle movements from a set of 2D recorded images, a rendering method based on the 2D discrete Fourier transform is applied. Promising preliminary results have been obtained on some patients, and a clinical study on a great number of subjects (both healthy and heart complaint people) was carried out.
引用
收藏
页码:1527 / 1538
页数:12
相关论文
共 50 条
[21]  
Hyukje Kweon, 1992, Proceedings of the 1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, P1263, DOI 10.1109/IEMBS.1992.594813
[22]   DESIGN OF SLOTTED TRANSDUCER ARRAYS WITH MATCHED BACKINGS [J].
KINO, GS ;
DESILETS, CS .
ULTRASONIC IMAGING, 1979, 1 (03) :189-209
[23]  
LEEMAN S, 1987, PAT REC ACOUS IMAG, V13, P173
[24]   Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming [J].
Lockwood, GR ;
Talman, JR ;
Brunke, SS .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (04) :980-988
[25]   VENTRICULAR VOLUME MEASUREMENT FROM A MULTIPLANAR TRANSESOPHAGEAL ULTRASONIC-IMAGING SYSTEM - AN INVITRO STUDY [J].
MARTIN, RW ;
BASHEIN, G ;
DETMER, PR ;
MORITZ, WE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (05) :442-449
[26]   3 DIMENSIONAL ECHOCARDIOGRAPHY FOR SPATIAL VISUALIZATION AND VOLUME CALCULATION OF CARDIAC STRUCTURES [J].
MATSUMOTO, M ;
INOUE, M ;
TAMURA, S ;
TANAKA, K ;
ABE, H .
JOURNAL OF CLINICAL ULTRASOUND, 1981, 9 (04) :157-165
[27]   MULTIDIMENSIONAL ULTRASONIC-IMAGING FOR CARDIOLOGY [J].
MCCANN, HA ;
SHARP, JC ;
KINTER, TM ;
MCEWAN, CN ;
BARILLOT, C ;
GREENLEAF, JF .
PROCEEDINGS OF THE IEEE, 1988, 76 (09) :1063-1073
[28]  
Nelson TR, 1996, J ULTRAS MED, V15, P1
[29]  
NELSON TR, 1994, MED PHYS, V21, P998
[30]   Accurate measurement of left ventricular ejection fraction by three-dimensional echocardiography - A comparison with radionuclide angiography [J].
Nosir, YFM ;
Fioretti, PM ;
Vletter, WB ;
Boersman, E ;
Salustri, A ;
Postman, JT ;
Reijs, AEM ;
TenCate, FJ ;
Roelandt, JRTC .
CIRCULATION, 1996, 94 (03) :460-466